Tray Cell for ultra-micro sample volumes from 0.7 to 5 microlitres compatible with Genova, 6705 and 6715 spectrophotometers, supplied complete with caps for 1mm and 0.2mm pathlength operation
• Ideal for DNA, RNA and protein measurements
• Sample volumes as low as 0.7µl
• Sample concentration range from 25 to 4250µg/ml
• Sample is simply wiped away after the measurements, making the TrayCell quick and easy to use
• Prevents dilution and pipetting errors
• Fits all standard 10 x 10mm cuvette holders
The TrayCell is a fibre optic cuvette which can be used with as little as 0.7µl of sample. The cuvette has two caps which give path lengths of either 1mm or 0.2mm, thus creating a "virtual
dilution" of 1:10 or 1:50 of the sample when compared to a measurement with a standard 10 mm cuvette.
Technical Specification
Parameter |
TrayCell |
Light Path |
0.2mm or 1mm |
Error of light path |
± 0.02mm |
Volume |
0.7–5µl |
Wavelength range |
190 to 1100nm |
Maximum temperature |
50°C |
Ordering Information
Part Code |
Description |
035 262 |
Tray Cell for ultra–micro sample volumes from 0.7 to 5µl compatible with Genova, 6705 and 6715 spectrophotometers, supplied complete with caps for 1mm and 0.2mm path length operation |
035 263 |
Replacement 1mm path length cap for TrayCell |
035 264 |
Replacement 0.2mm path length cap for TrayCell |
Disposable Cuvettes and Test Tubes
Part Code |
Description |
060 084 |
Pack of 100 plastic cuvettes, visible wavelengths only, 2.4 to 4.5ml fill volume |
060 229 |
Pack of 500 plastic cuvettes (5 boxes of 060 084) |
060 087 |
Pack of 100 plastic cuvettes, visible wavelengths only, 1.5 to 3.0ml fill volume |
060 230 |
Pack of 100 plastic cuvettes, UV and visible wavelengths, 2.5 to 4.5ml fill volume |
060 232 |
Pack of 500 plastic cuvettes (5 boxes of 060 230) |
060 231 |
Pack of 100 UV plastic cuvettes, 1.5 to 3.0ml fill volume |
035 143 |
Pack of 100 plastic cuvettes, UV and visible wavelengths, 70µl to 1.5ml fill volume (use with micro cuvette holder) |
060 331 |
Pack of 100 glass test tubes (12 x 75mm) |
060 179 |
Pack of 100 plastic test tubes (12 x 75mm) |
060 335 |
Pack of 50 glass test tubes (24 x 150mm) |
Glass and Quartz Cuvettes
Part Code |
Description |
035 027 |
Visible (glass) 10mm path length cuvette |
035 086 |
Visible (glass) 20mm path length cuvette |
035 029 |
Visible (glass) 40mm path length cuvette |
035 087 |
Visible (glass) 50mm path length cuvette |
035 079 |
Visible (glass) 100mm path length cuvette |
035 123 |
Visible (glass) micro (500µl) cuvette |
035 126 |
Visible (glass) semi-micro (1ml) cuvette |
035 028 |
UV (quartz) cuvette (2.0 to 3.5ml) |
035 124 |
UV (quartz) ultra micro (50µl) cuvette |
035 125 |
UV (quartz) micro (500µl) cuvette |
035 127 |
UV (quartz) semi-micro (1ml) cuvette |
035 138 |
UV (quartz) ultra-micro (100µl) cuvette |
035 139 |
UV (quartz) ultra-micro (200µl) cuvette |
035 249 |
UV (quartz) ultra-micro (20µl) cuvette |
Flow Cells
Part Code |
Description |
035 026 |
Pour in/Suck out cell |
035 025 |
Visible (glass) flow-through cell 1.8ml |
035 045 |
Visible (glass) flow-through cell 80µl |
035 044 |
UV (quartz) flow-through cell 1.8ml |
035 047 |
UV (quartz) flow-through cell 80µl |
Spectrophotometers - Jenway
|
?67 Series Spectrophotometers
• Colour touch screen display
• High quality, sealed split beam optics for optimum photometric performance
• Secure multi-user operation
• Save to SD memory cards
• Enhanced productivity
• Extensive range of accessories for flexibility and improve productivity
There are three models in the 67 series - Model 6700 covers the visible range of the spectrum and has a 4nm bandwidth; Models 6705 and 6715 cover the UV/visible range of the spectrum and have a 4nm and 1.5nm bandwidth respectively. All three instruments have modes for photometrics, spectrum scanning, multi-wavelength analysis, kinetics and quantitation, giving direct concentration results against single or multi-point calibrations. With extensive post measurement tools to ensure results are presented exactly to each users requirements the 67 series spectrophotometers also offer significant advances in data portability.
Together, the touch screen and colour display give the fastest, most flexible instrument interface possible. Where fine cursor control is required, using the QWheel™ makes the task easy and precise.
Jenway have developed Secure Multi User Operation for when instruments are shared by a number of users, so access to the instrument functions is controlled through a secure log-in procedure. For maximum security PIN codes can be allocated to individuals, groups or departments and to further increase flexibility each method can be given three levels of security:
• Public access is free to all users.
• Read only methods can be accessed by all users, but only modified by the originator.
• Personal method can only be accessed by the logged in user
The high capacity internal memory of the 67 series enables over 500 methods and results to be stored. Removable SD cards further increases the flexibility and data transfer and enables the direct transfer of results to a PC via a USB port. Here all data can be viewed, exported, saved or printed for generating reports and standard operating procedures. Copying the SD card to the instrument's internal memory enables the easy cloning of multiple instruments, ensuring common laboratory practice and speeding set-up in busy teaching establishments.
QWheel is a registered trademark of Quantum Research.
Technical Information
Model |
6700, 6705 and 6715 |
Wavelength range |
320 to 1100nm (6700), 190 to 1100nm (6705, 6715) |
Wavelength resolution |
0.1nm |
Wavelength accuracy |
±1.0nm |
Wavelength repeatability |
±0.2nm |
Spectral bandwidth |
4nm (6700, 6705), 1.5nm (6715) |
Transmittance |
0 to 199.9%T |
Absorbance |
–0.300 to 3.000A |
Accuracy |
±0.005A at 1.0A |
Resolution |
0.1%T, 0.001A |
Stray light |
<0.1%T at 340nm (6700), <0.05% at 220nm (6705, 6715) |
Noise |
<0.001 at 0A, <0.002 at 2A at 340nm |
Stability |
<0.001A/h after warm–up |
Quantitation range |
–99999 to +99999 |
Quantitation resolution |
Selectable 1, 0.1, 0.01 or 0.001 |
Calibration |
Up to 20 with 5 replicates of each |
Units |
mEq/l, ppm, mg/l, g/l, %, µg/ml, mg/ml, g/dl, mg/dl, µg/l, ng/l, µg/dl, M, mM, µM, U/l, mU/l, U/ml, blank |
Curve fit algorithms |
Linear, quadratic and cubic functions |
Multi–wavelength |
Up to 4 wavelengths |
Calculations |
Ratio, difference, formulae with factors |
Kinetics time limits |
0 to 9999 seconds |
Calibration |
Standard or factor |
Analysis |
Curve details with mean rate of change plus formula of line of best fit |
Spectrum range |
Any range between 320 (6700) or 190 (6705, 6715) and 1100nm |
Scan speed |
1500nm/min |
Scan interval |
0.1nm |
Analysis |
Auto peaks and valleys, zoom, addition, subtraction, peak ratios, smoothing, area under curve, wavelength table, derivatives, analysis points, overlay |
Light source |
Tungsten halogen lamp (6700), Xenon lamp (6705, 6715) |
Configuration |
Secure multi–user and free access |
Number of users |
10 users + supervisor |
Methods/results memory |
>1000 on internal flash memory or removable media |
Removable media |
MM/SD memory card or SD/USB memory card |
Outputs |
USB, Centronics, Analogue |
Size (w x d x h) |
490 x 390 x 220mm |
Weight |
7.5kg |
|
Spectrophotometers - Jenway
|
Genova Plus Life Science Spectrophotometer
• 5nm spectral bandwidth
• Absorbance range -0.3 to 2.5A
• Pre-programmed for DNA/RNA analysis
• Purity scan across entire wavelength range
• Pre-programmed methods for protein analysis
• Standard spectrophotometer functions
• Press to read xenon lamp
• Icon driven software
• Small footprint
• Method and result saving to USB memory stick
• 3 year warranty including xenon lamp
The new Genova Plus is a UV/visible spectrophotometer dedicated to life science analysis. This spectrophotometer allows the measurement of DNA concentrations and purity ratios using wavelengths recorded at 260, 280 and 230nm, with an optional correction at 320nm. The Genova Plus is pre-programmed with Bradford, Lowry, Biuret, BCA and Direct UV methods for protein analysis. The Genova Plus has an OD measurement mode enabling cell growth to be monitored by measuring absorbance at 600nm, 595nm or any other user selected wavelength. The purity scan across the entire wavelength range from 198 to 1000nm displays any distorted peaks enabling impurities to be easily identified.
This life science spectrophotometer uses icon driven software and has an improved navigation system for easy and intuitive usability. As well as the dedicated life science measurement modes this instrument can also be used as a standard spectrophotometer with measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, quantitation and kinetics.
Technical Information
Model |
Genova |
Parameter |
Genova Plus |
Wavelength Range |
198 to 1000nm |
Light source |
Xenon lamp |
Wavelength Resolution |
1nm |
Wavelength Accuracy |
± 2nm |
Wavelength Repeatibility |
± 0.5nm |
Spectral bandwidth |
5nm |
Photometric Transmittance |
0 to 199.9% |
Photometric Absorbance |
- 0.300 to 2.500 |
Photometric Accuracy* |
± 1%T, ± 0.01Abs at 1.000 Absorbance |
Photometric Resolution |
0.1%T, 0.001A |
Concentration/Quantitation Range |
0 to 9999 |
Concentation Calibration |
Blank with a single standard or factor |
Quantitation Calibration |
Blank with up to 12 standards |
Quantitation Curve fit algorithms |
Quadratic, quadratic through zero, linear, linear through zero, interpolate |
Kinetics Measurement time |
2 to 9999 seconds |
Kinetics Calibration |
Blank with a single standard or factor |
Kinetics Display |
Graphical and concentration |
Kinetics Analysis |
Concentration, rate of change, initial and final absorbance/ %T |
Spectrum/Purity Range |
198 to 1000nm |
Scan interval |
selec table 1, 2 or 5nm |
Spectrum/Purity Analysis |
Absorbance or transmittance and peak and valleys |
Multi-wavelength Data Points |
Up to 4 wavelengths |
Multi-wavelength Calculations |
Sum, product, ratio and difference |
DNA Measurement Modes |
dsDNA, ssDNA, RNA, Oligonucleotides, 260/ 280, 260/ 230, Variable ratio |
Multi-wavelength Plus Data Points |
Up to 3 wavelengths plus optional reference wavelength |
Multi-wavelength Plus Calculations |
Concentration and ratio |
Protein Measurement Modes |
BCA, Bradford, Lowry, Biuret, Direct UV |
OD 600 Range |
0.00 E- 19 to 9.99 E+ 19 |
OD 600 Calibration |
Blank with a single standard or factor |
GLP Support |
Current time and date, user ID, instrument lock and method lock |
Method storage |
312 (including pre-programmed methods) |
Results memory |
Limited by attached mass storage device |
Removable media |
USB (supplied) |
Outputs |
USB, Analogue, RS232, Integral printer |
Size (w x d x h) |
275 x 400 x 220mm |
Weight |
6kg |
|
Visible Light Spectrophotometers
Anadeo Features
|
- Easy to use keypad.
- Compact and lightweight.
- Choice of 3 models.
- Excellent optical performances.
- 50 programmable memories.
- Large clear LCD and intuitive Navigation system.
|
Anadeo 1
Absorbance, transmittance and calculation of concentration by linear regression using known factor or 1 standard.
Anadeo Plus
Includes all the features of the Anadeo 1, plus the following methods of measurement:
Concentration
- Use of factor or up to 8 standards
- Display of the factor and intercept
Kinetics
- Initial delay, time and number intervals
- Display of the average and intermediate interval slopes
- Calculation of activity
Multi-wavelengths
- Display of absorbances, ratio and difference (delta) of absorbance
Anadeo Clinical
Same features as Anadeo Plus but includes a 37°C thermostatic chamber and aspiration system for clinical applications.
Anadeo Range - Technical Specification & Ordering Information
MODEL |
Anadeo 1
|
Anadeo Plus
|
Anadeo Clinical
|
Spectral Range |
330 to 900 nm
|
330 to 900 nm
|
330 to 900 nm
|
Absorbance |
Yes
|
Yes
|
Yes
|
Transmittance |
Yes
|
Yes
|
Yes
|
Concentration |
Yes
|
Yes
|
Yes
|
Factors / Standards |
1 factor/1 standard
|
1 factor/1 to 8 standards
|
1 factor/1 to 8 standards
|
Kinetics (initial delay, interval time, number of intervals, activity calculation) |
Yes
|
Yes
|
Yes
|
Multi-wavelengths (ratio and delta) |
-
|
Yes
|
Yes
|
Thermostated chamber at 37°C |
-
|
-
|
Yes
|
Programmable Aspiration System |
-
|
-
|
Yes
|
Cuvette Holder |
1 x 10 mm cuvette holder
|
Bandpass |
< 10 mm
|
Accuracy |
± 1.5 NM
|
Repeatability |
± 1 NM
|
Photometric range |
-0.3 to 2.500 Abs, 0.3 to 200% T
|
Accuracy |
± 2%
|
Drift |
< 0.003 A/h at 500 NM
|
Stray light |
0.5% at 340 and 400 NM
|
Display |
Alphanumerical, back-lit LCD, 8 mm digits, 2 lines 16 characters
|
Zero |
Automatic
|
Programmable memories |
50 methods with parameters
|
Light source |
Tungsten-halogen lamp
|
Monochromator |
Protected grating Jobin Yvon®
|
Detector |
Silicon diode
|
Output |
Serial RS232C 9 pins
|
Power |
230V/60Hz
|
Dimensions (w x d x h) |
180 x 280 x 220 mm
|
Weight |
2.5Kg
|
5.2Kg
|
6Kg
|
Ordering Information |
ANADEO1
|
ANADEO2
|
ANADEO3
|
Each Anadeo unit is delivered complete with: 100 Sterilin plastic cuvettes, 1 power transformer, 1 user manual.
Spares
Description |
Product Number |
Pack Quantity |
Tungsten Halogen Lamp |
ANA034 |
1 |
Printer Ribbons |
ANA6931 |
2 |
Printer Paper Rolls |
ANA6928 |
5 |
Optional Accessories
Each accessory snaps into place quickly and easily using our unique clip system for which no tools are necessary.
Description |
Product Number |
Pack Quantity |
Sterilin® Disposable Cuvettes |
221M |
5 x 100 |
Holder for two cuvettes, 10mm * |
ANA385 |
1 |
Test-Tube Block, 16mm |
ANA384 |
1 |
Adapter, 12V, for car lighter |
SM27/3 |
1 |
Thermic Printer |
ANA6910 |
1
|
6500 & 6505 Spectrophotometers
High performance split beam optics
|
|
1.8nm bandwidth
|
|
Spectral addition and subtraction
|
|
1st-4th derivative and post scan analysis
|
|
Method and results storage
|
|
Application and data storage cards
|
|
The 6500 series are multi-capability scanning spectrophotometers designed to provide the user with a high quality system which offers all the features required by a scientist to manipulate and process spectral information.
The Model 6500 Visible range unit operates at 320-1100nm.
The Model 6505 UV/Visible range unit operates at 190-1100nm.
|
Features include:
A customised LCD gives a clear readout of calibration data, sample data and all set-up options.
Simple keypad layout and operating protocols facilitates the setting of experimental parameters and initiating sample analysis procedures.
Graphical user interface (GUI) allows interactive control of all operating parameters. Both keypad and mouse operation are fully supported.
Multi-language capability allows screen instructions to be presented in a choice of English, French, German, Italian, Portuguese and Spanish.
Five operating ranges are available - photometrics, spectrum, kinetics, multi-wavelength and quantitation.
Full kinetics capability allows, usually in conjunction with the peltier cell block, full analysis of timed reactions
Calibration curves producing non-linear results can also be accommodated using in-built software. Up to twenty data points (standards), or up to seven when using the multi-cell changer, can be determined automatically and used to construct a calibration curve. A variety of statistical methods are available to ensure a close correlation to all curve shapes.
Full scanning capability allows scan range, speed and resolution to be user adjusted and the resultant scan to be auto scaled for enhanced visibility. Peaks and valleys are labelled with wavelength and absorbance values and can be readily down loaded to the optional internal printer, to a PC or a Centronics printer. A cursor facility allows the user to interrogate specific parts of the scanned data
An integral printer module is available and can be supplied as a factory fitted item at the time of ordering the product or as a customer installable module.
Full interfacing capability using RS232 interfacing or an analogue output is provided as standard. Utilising the RS232 facility allows results to be down loaded via the front panel print key.
Both models incorporate a bi-directional interface allowing remote operation, calibration and interrogation by an external computer.
An automatic results log allows readings to be stored in a data file either when the print key is pressed; at a user defined set time interval or by a multiple sample assay using the 8 position cell holder. Data files have a user entered ID and can be saved in internal memory or to an external data card. Results saved in internal memory can be transferred to an external data card.
Method storage allows all user set parameters to be saved against a user identification. A method can be subsequently recalled which configures the instrument to the saved parameters. The instrument settings for a recalled method can be altered and subsequently saved against the same or a different method identification. Methods can be saved in internal memory or to an external memory card. Methods saved in internal memory can be transferred to an external data card. The instruments memory has the capacity to store a minimum of fifty methods.
Traceable calibration standards provide the on-going assurance of accuracy required by Good Laboratory Practice (G.L.P.). A user set identification number (up to 20 digits in length) is entered and will be shown on any printouts produced by the instrument. In addition, each printout will show sample number, reading, unit of measurement, the wavelength analysis and the current time and date. Scans and concentration curves stored will also be time and date stamped. The 6500 series complies fully with EEC and US directives relating to ESD/EMC emission and susceptibility
6400 & 6405 Spectrophotometers
|
Single beam scanning
|
|
5nm bandwidth
|
|
Multi-wavelength and kinetics analysis
|
|
Wide range of sampling accessories
|
|
Full interfacing capability
|
|
Optional 8 position multi-cell changer (quantitation measurement)
|
|
|
The 6400 series incorporate a wide range of features designed to satisfy the needs of users seeking to maximise the efficiency of routine and specialised UV and visible spectroscopy tasks.
The Model 6400 Visible range unit operates at 320-1100nm.
The Model 6405 UV/Visible range unit operates at 190-1100nm.
|
Features include:
A customised LCD gives a clear readout of calibration data, sample data and all set-up options.
Simple keypad layout and operating protocols facilitates the setting of experimental parameters and initiating sample analysis procedures.
Multi-language capability allows screen instructions to be presented in a choice of English, French, German, Italian, Portuguese and Spanish.
Five operating ranges are available - photometrics, spectrum, kinetics, multi-wavelength and quantitation.
Full kinetics capability allows , usually in conjunction with the peltier cell block, full analysis of timed reactions
Calibration curves producing non-linear results can also be accommodated using in-built software and the multi-cell changer. Up to seven data points can be determined automatically and used to construct a calibration curve. A variety of statistical methods are available to ensure a close correlation to all curve shapes.
Full scanning capability allows scan range, speed and resolution to be user adjusted and the resultant scan to be auto scaled for enhanced visibility. Peaks and valleys are labelled with wavelength and absorbance values and can be readily down loaded to the optional internal printer, to a PC or a Centronics printer.
Sample presentation flexibility is a key feature, with cells from 100mm path length down to micro sample capacity being readily accommodated.
An integral printer module is available and can be supplied as a factory fitted item at the time of ordering the product or as a customer installable module.
Full interfacing capability using RS232 interfacing or an analogue output is provided as standard. Utilising the RS232 facility allows results to be down loaded via the front panel print key.
Both models incorporate a bi-directional interface allowing remote operation, calibration and interrogation by an external computer.
Traceable calibration standards provide the on-going assurance of accuracy required by Good Laboratory Practice (G.L.P.). A user set identification number (up to 6 digits in length) is entered and will be shown on any printouts produced by the instrument. In addition, each printout will show sample number, reading, unit of measurement, the wavelength analysis and the current time and date. Scans and concentration curves stored will also be time and date stamped. The 6400 series complies fully with EEC and US directives relating to ESD/EMC emission and susceptibility.
Spectrophotometers - Jenway
|
?New 7310 and 7315 Spectrophotometers
• Icon driven software
• Results and method saving to USB memory stick
• Autologging capabilities
• Press to read xenon lamp (7315)
• 3 year warranty including xenon lamp
• Extensive range of accessories available
The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system for easy and intuitive usability. The range includes two basic models, 7300 and 7305 and two advanced models, 7310 and 7315. The 7310 and 7315 feature measurement modes for absorbance, % transmittance, concentration, spectrum scanning, kinetics and quantitation.
The advanced models have the additional feature of an easy access USB port on the front of the unit which enables results to be stored directly to a USB memory stick for easy transfer of data. These models can also store up to 240 methods which can be copied from one unit to another using the USB capability.
The 7310 and 7315 models have enhanced security features enabling the settings and methods to be locked preventing unauthorised changes to the instrument settings and method parameters. The home page can also be customised and selected modes restricted, which is ideal for teaching laboratories.
The 73 series spectrophotometers are all covered by a three year warranty which includes the xenon lamp.
Technical Information
Model |
7310 |
7315 |
Wavelength Range |
320 to 1000nm |
198 to 1000nm |
Light source |
Tungsten halogen lamp |
Xenon lamp |
Resolution |
1nm |
1nm |
Accuracy |
± 2nm |
± 2nm |
Repeatibility |
± 0.5nm |
± 0.5nm |
Spectral bandwidth |
5nm |
5nm |
Photometric Transmittance |
0 to 199.9% |
0 to 199.9% |
Photometric Absorbance |
-0.300 to 2.500 |
-0.300 to 2.500 |
Photometric Accuracy |
± 1%T, ± 0.01Abs at 1.000 Absorbance |
± 1%T, ± 0.01Abs at 1.000 Absorbance |
Photometric Resolution |
0.1%T, 0.001A |
0.1%T, 0.001A |
Concentration Range |
-300 to 9999 |
-300 to 9999 |
Concentration Resolution |
selec table 1/ 0.1/ 0.01/ 0.001 |
selec table 1/ 0.1/ 0.01/ 0.001 |
Concentation Calibration |
Blank with a single standard or factor |
Blank with a single standard or factor |
Concentration Units |
no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l |
no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l |
Concentration Factor |
0.001 to 10000 |
0.001 to 10000 |
Concentration Standard |
0.001 to 1000 |
0.001 to 1000 |
Quantitation Range |
-300 to 9999 |
-300 to 9999 |
Quantitation Resolution |
selec table 1/ 0.1/ 0.01/ 0.001 |
selec table 1/ 0.1/ 0.01/ 0.001 |
Quantitation Calibration |
Blank with up to 6 standards |
Blank with up to 6 standards |
Quantitation Curve fit algorithms |
Quadratic, quadratic through zero, linear, linear through zero, interpolate |
Quadratic, quadratic through zero, linear, linear through zero, interpolate |
Kinetics Measurement time |
2 to 9999 seconds |
2 to 9999 seconds |
Kinetics Calibration |
Blank with a single standard or factor |
Blank with a single standard or factor |
Kinetics Display |
Graphical and concentration |
Graphical and concentration |
Kinetics Analysis |
Concentration, rate of change, initial and final absorbance/%T |
Concentration, rate of change, initial and final absorbance/:%T |
Kinetics Resolution |
selec table 1/ 0.1/ 0.01/ 0.001 |
selec table 1/ 0.1/ 0.01/ 0.001 |
Spectrum Range |
320 to 1000nm |
198 to 1000nm |
Spectrum Scan interval |
selec table 1, 2 or 5nm |
selec table 1, 2 or 5nm |
Spectrum Analysis |
Absorbance or transmittance and peak and valleys |
Absorbance or transmittance and peak and valleys |
GLP |
Current time and date, user ID, instrument lock and method lock |
Current time and date, user ID, instrument lock and method lock |
Method storage |
240 |
240 |
Results memory |
Limited by attached mass storage device |
Limited by attached mass storage device |
Removable media |
USB (supplied) |
USB (supplied) |
Outputs |
USB, Analogue, RS232, Integral printer |
USB, Analogue, RS232, Integral printer |
Size (w x d x h) |
275 x 400 x 220mm |
275 x 400 x 220mm |
Weight |
6kg |
6kg
|
|
Spectrophotometers - Jenway
|
?New 7300 and 7305 Spectrophotometers
• Icon driven software
• Small footprint
• Autologging capabilities
• Press to read xenon lamp (7305)
• Extensive range of accessories available
The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system for easy and intuitive usability. The range includes two basic models, 7300 and 7305 and two advanced models, 7310 and 7315. The 7300 and 7305 feature measurement modes for absorbance, % transmittance and concentration.
All of the models in the 73 series range are covered by a three year warranty which includes the xenon lamp. These spectrophotometers are easy to use and ideal for use in education and general QC laboratories.
Technical Information
Model |
7300 |
7305 |
Wavelength Range |
320 to 1000nm |
198 to 1000nm |
Light source |
Tungsten halogen lamp |
Xenon lamp |
Resolution |
1nm |
1nm |
Accuracy |
± 2nm |
± 2nm |
Repeatibility |
± 0.5nm |
± 0.5nm |
Spectral bandwidth |
5nm |
5nm |
Photometric Transmittance |
0 to 199.9% |
0 to 199.9% |
Photometric Absorbance |
-0.300 to 2.500 |
-0.300 to 2.500 |
Photometric Accuracy |
± 1%T, ± 0.01Abs at 1.000 Absorbance |
± 1%T, ± 0.01Abs at 1.000 Absorbance |
Photometric Resolution |
0.1%T, 0.001A |
0.1%T, 0.001A |
Concentration Range |
-300 to 9999 |
-300 to 9999 |
Concentration Resolution |
Selectable 1/0.1/0.01/0.001 |
Selectable 1/0.1/0.01/0.001 |
Concentation Calibration |
Blank with a single standard or factor |
Blank with a single standard or factor |
Concentration Units |
no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l |
no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l |
Concentration Factor |
0.001 to 10000 |
0.001 to 10000 |
Concentration Standard |
0.001 to 1000 |
0.001 to 1000 |
Outputs |
Analogue, RS232, Integral printer |
Analogue, RS232, Integral printer |
Size (w x d x h) |
275 x 400 x 220mm |
275 x 400 x 220mm |
Weight |
6kg |
6kg
|
|
Spectrophotometers - Jenway
|
?6300 and 6320D Visible UV/Vis Spectrophotometers
• Wavelength range of 320 to 1000nm (6300 and 6320D)
• Absorbance, %T and concentration modes
• Multi-parameter display with wavelength and photometric readouts
• Wide range of sampling accessories
• Domed lid of 6320D accepts tubes up to 105mm tall
• 6305 utilises a high quality pulsed xenon lamp
• Wide range of sampling accessories
The 6300 is high quality, low cost unit for spectrophotometric applications in schools and colleges, as well as in QC and testing procedures for a wide variety of services and industries. The 6320D is based on the 6300 platform and includes a domed lid which accepts taller tubes up to a height of 105mm.
Technical Information
Model |
6300 and 6320D |
Wavelength range |
320 to 1000nm |
Wavelength resolution |
1nm |
Wavelength accuracy |
±2nm |
Spectral bandwidth |
8nm |
Transmittance |
0 to 199.9%T |
Absorbance |
–0.300 to 1.999A |
Accuracy |
±1%T |
Resolution |
0.1%T, 0.001A |
Stray light |
<0.5%T |
Noise |
<1% |
Stability |
1%/h after 15 minutes |
Concentration range |
–300 to 1999 |
Concentration resolution |
0.1 to 1 |
Units |
ppm, mg/l, g/l, M, %, blank |
Factor |
0 to 199.9, 1000 to 9999 |
Light source |
Tungsten halogen lamp |
Outputs |
Analogue and RS232 |
Power |
<50W |
Size (w x d x h) |
365 x 272 x 160mm |
Weight |
6kg
|
|
Models S-20 Vis & S-22 UV/Vis
Model S-20 Vis |
Code / Description |
Model S-22 UV/Vis |
Code / Description |
BOE 8630501 230V
BOE 8630531 110V |
Spectrophotometer, with pack 100 10x10mm plastic cuvettes, mains lead, 10x10 cell holder & manual |
BOE 8630501 230V
BOE 8630531 110V |
Spectrophotometer, with pack 100 10x10mm plastic cuvettes, mains lead, 10x10 cell holder & manual |
Wavelength ranges: |
|
320 - 1000 nm (S-20) |
198 - 1000 nm (S-22) |
|
Bandwidths: |
|
8 nm (S-20) |
6 nm (S-22) |
|
In-built wavelength calibration |
|
Automatic O%T setting during all calibration routines |
|
Dual display - wavelength & photometric result |
|
Full interfacing capability |
|
(bi-directional RS 232 interface) |
|
Versatile sampling system |
|
Simple operation |
|
Ideal for Routine Analysis |
|
First quality at affordable prices |
|
Manufactured under ISO 9000 norms |
|
CE mark for electromagnetic compatibility |
|
The BOECO Model S-22 has a unique xenon lamp
which has the advantage of offering a broad spectral
source with extended life. This enables the running
costs for the S-22 to be minimised over the lifetime of
the spectrophotometer, since there are no deuterium
and tungsten lamps to replace. |
|
|
Single lamp with guaranteed 3 year life time |
|
Self calibrating lamp at 3 wavelengths |
|
10 times more UV light energy |
|
Blazed holographic grating
|
Anadeo Range
Easy to use keypad.
Compact and lightweight.
Choice of 3 models.
Excellent optical performances.
50 programmable memories.
Large clear LCD and intuitive Navigation system.
Anadeo 1
Absorbance, transmittance and calculation of concentration by linear regression using known factor or 1 standard.
Anadeo Plus
Includes all the features of the Anadeo 1, plus the following methods of measurement:
Concentration
Use of factor or up to 8 standards
Display of the factor and intercept
Kinetics
Initial delay, time and number intervals
Display of the average and intermediate interval slopes
Calculation of activity
Multi-wavelengths
Display of absorbances, ratio and difference (delta) of absorbance
Anadeo Clinical
Same features as Anadeo Plus but includes a 37°C thermostatic chamber and aspiration system for clinical applications.
Anadeo Range - Technical Specification & Ordering Information
MODEL |
Anadeo 1
|
Anadeo Plus
|
Anadeo Clinical
|
Spectral Range |
330 to 900 nm
|
330 to 900 nm
|
330 to 900 nm
|
Absorbance |
Yes
|
Yes
|
Yes
|
Transmittance |
Yes
|
Yes
|
Yes
|
Concentration |
Yes
|
Yes
|
Yes
|
Factors / Standards |
1 factor/1 standard
|
1 factor/1 to 8 standards
|
1 factor/1 to 8 standards
|
Kinetics (initial delay, interval time, number of intervals, activity calculation) |
Yes
|
Yes
|
Yes
|
Multi-wavelengths (ratio and delta) |
-
|
Yes
|
Yes
|
Thermostated chamber at 37°C |
-
|
-
|
Yes
|
Programmable Aspiration System |
-
|
-
|
Yes
|
Cuvette Holder |
1 x 10 mm cuvette holder
|
Bandpass |
< 10 mm
|
Accuracy |
± 1.5 NM
|
Repeatability |
± 1 NM
|
Photometric range |
-0.3 to 2.500 Abs, 0.3 to 200% T
|
Accuracy |
± 2%
|
Drift |
< 0.003 A/h at 500 NM
|
Stray light |
0.5% at 340 and 400 NM
|
Display |
Alphanumerical, back-lit LCD, 8 mm digits, 2 lines 16 characters
|
Zero |
Automatic
|
Programmable memories |
50 methods with parameters
|
Light source |
Tungsten-halogen lamp
|
Monochromator |
Protected grating Jobin Yvon®
|
Detector |
Silicon diode
|
Output |
Serial RS232C 9 pins
|
Power |
230V/60Hz
|
Dimensions (w x d x h) |
180 x 280 x 220 mm
|
Weight |
2.5Kg
|
5.2Kg
|
6Kg
|
Ordering Information |
ANADEO1
|
ANADEO2
|
ANADEO3
|
Each Anadeo unit is delivered complete with: 100 Sterilin plastic cuvettes, 1 power transformer, 1 user manual.
Spares
Description |
Product Number |
Pack Quantity |
Tungsten Halogen Lamp |
ANA034 |
1 |
Printer Ribbons |
ANA6931 |
2 |
Printer Paper Rolls |
ANA6928 |
5 |
Optional Accessories
Each accessory snaps into place quickly and easily using our unique clip system for which no tools are necessary.
Description |
Product Number |
Pack Quantity |
Sterilin® Disposable Cuvettes |
221M |
5 x 100 |
Holder for two cuvettes, 10mm * |
ANA385 |
1 |
Test-Tube Block, 16mm |
ANA384 |
1 |
Adapter, 12V, for car lighter |
SM27/3 |
1 |
Thermal Printer |
ANA6910 |
1 |
Specifications
|
|
|
|
|
S-20 Vis |
S-22 UV/Vis |
Range |
320 - 1000 nm |
198 - 1000 nm |
Resolution |
1nm |
1nm |
Accuracy |
± 2 nm |
± 2 nm |
Bandwith |
8 nm |
6 nm |
|
|
|
|
|
|
|
|
|
|
S-20 Vis |
S-22 UV/Vis |
Range |
-0.300 to 1.999 A |
-0.300 to 1.999A |
Resolution |
0.1 % |
0.1 % |
Stray Light |
<0,5% @ 340 nm |
<0.5% @ 340 nm |
Photometric Accuracy |
± 1% |
± 1% |
|
|
|
|
|
|
|
|
|
S-20 Vis |
S-22 UV/Vis |
Range |
-300 to 1999 Concentration |
-300 to 1999 Concentration |
Resolution |
0.1 / 1 |
0.1 / 1 |
Units |
ppm, mg/l, g/l, M, %, blank |
ppm, mg/l, g/l, M, %, blank |
|
|
|
|
|
|
|
|
|
S-20 Vis |
S-22 UV/Vis |
Factor |
0 to 999.9, 1000 to 9999 |
0 to 999.9, 1000 to 9999 |
Photometric Noise Levels |
<1% |
<1% |
Photometric Stability |
1%/Hour after warm-up |
1%/Hour after warm-up |
Readout |
Custom Liquid Crystal Display |
Custom Liquid Crystal Display |
Outputs |
Analog (0 to 1999mV) /
RS232 serial port |
Analog (0 to 1999mV) /
RS232 serial port |
Light Source |
Tungsten Halogen 20W 12V |
Xenon Lamp module |
Input Voltage |
115/230V AC -20% +10% |
115/230V AC -20% +10% |
Input Power |
<50W |
<50W |
Size |
365(W)x272(D)x166(H) mm |
365(W)x272(D)x166(H) mm |
Weight |
6 kgs |
6 kgs
|
|
|
Jenway Model 6800 1.5nm Bandwidth Spectrophotometer
True Double Beam with highly stable optics
1.5nm spectral bandwidth
Includes Jenway Flight Deck Software
A range of easy to fit accessories
The Jenway Model 6800 is built on a solid foundation of high quality, sealed optics for optimum photometric performance.
The user-friendly Flight Deck software delivers the intuitive operation you have come to expect from Jenway instruments; while the operator-focus ensures this spectrophotometer will meet the demands of your laboratory, today and into the future.
Specification
Light Source
|
Tungsten Halogen and Deuterium
|
Scan Speed
|
10 to 3600nm/min
|
Spectral Bandwidth
|
1.5nm
|
Lamp Switchover
|
370 to 325nm
|
Wavelength Range
|
190-1100nm
|
Wavelength Accuracy
|
±0.3nm
|
Wavelength Reproducibility
|
±0.1nm
|
Stray Light
|
<0.05% at 340nm and 220nm
|
Operating Modes
|
Photometrics (includes Multiwavelength), Spectrum, Kinetics and Time Scan, Quantitation, DNA/RNA and Protein
|
Photometric Range
|
-3.000 to 3.000A
|
Photometric Accuracy
|
±0.002A
|
Photometric Reproducibility
|
±0.001A
|
Jenway Model 6700, 6705 and 6715 4nm Bandwidth Spectrophotometers
Colour (TFT) LCD with touch-screen interface
Sealed QWheelTMcontrol
Removable SD & SD/USB memory card
Plug-in accessory modules
Secure multi-user operation
Model 6700 covers the visible wavelength range with a spectral bandwidth of 4nm.
Model 6705 covers the UV/visible wavelength range with a spectral bandwidth of 4nm.
Model 6715 meets the EP/USP requirements with a spectral bandwidth of 1.5nm across the UV/visible wavelength range.
The large, colour touch-screen display ensures the fastest response to operator input and the clearest presentation of options and results. A sealed QWheelTM is provided for fine cursor control or scrolling. With this cutting-edge user interface and novel operating system the 67 series offer the simplest, most intuitive operation in their class.
Specification
Light Source
|
Tungsten Halogen (6700)
Xenon (6705/6715)
|
Optics
|
Sealed, MgF coated, split beam
|
Wavelength range
|
320-1100nm (6700) 190-1100nm (6705/6715)
|
Wavelength resolution
|
0.1nm
|
Wavelength accuracy
|
±1.0nm
|
Wavelength repeatability
|
±0.2nm
|
Spectral Bandwidth
|
4nm (6700/6705) 1.5nm (6715)
|
Stray Light
|
<0.1 at 340nm (6700) <0.05 at 220nm (6705/6715)
|
Photometric ranges
|
-0.300 to 3.000A & 0 to 199.9%T
|
Photometric resolution
|
0.001A & 0.1%T
|
Photometric accuracy
|
±0.005 at 1A
|
Photometric stability
|
<0.001A per hour
|
Quantitation range
|
-99999 to +99999
|
Number of Standards
|
20 with up to 5 replicates of each
|
Curve Fit Algorithms
|
Linear, Quadratic and Cubic functions
|
Jenway Model 6500 and 6505 1.8nm Bandwidth Spectrophotometers
High performance split beam optics
1.8nm bandwidth
Spectral addition and subtraction
1st-4th derivative and post scan analysis
Method and results storage
Application and data storage cards
The 6500 series are multi-capability scanning spectrophotometers designed to provide the user with a high quality system which offers all the features required by a scientist to manipulate and process spectral information.
The Model 6500 Visible range unit operates at 320-1100nm.
The Model 6505 UV/Visible range unit operates at 190-1100nm.
Features include:
A customised LCD gives a clear readout of calibration data, sample data and all set-up options.
Specification
Optics
|
Split beam
|
Wavelength range
|
320-1100nm (6500) / 190-1100nm (6505)
|
Resolution
|
0.1nm
|
Accuracy
|
±1.0nm
|
Bandwidth
|
1.8nm
|
Grating
|
1200 lines/mm
|
Transmittance range
|
0 to 199.9%T
|
Resolution
|
0.1%T
|
Accuracy
|
±1%T@10%T
|
Stray light
|
<0.05%T@340 & 220nm
|
Absorbance range
|
-0.300 to 3.000A
|
Resolution
|
0.001A
|
Accuracy
|
0.005A@1.0A
|
Concentration range
|
-300 to 9999Conc (resolution dependent)
|
Resolution
|
0.001 / 0.01 / 0.1 / 1
|
Units
|
ppb, ppm, µg/l, mg/l, M, %, blank
|
Factor
|
0.000 to 9999.99
|
Jenway Model 6400 and 6405 5nm Bandwidth Spectrophotometers
Single beam scanning
5nm bandwidth
Multi-wavelength and kinetics analysis
Wide range of sampling accessories
Full interfacing capability
Optional 8 position multi-cell changer (quantitation measurement)
The 6400 series incorporate a wide range of features designed to satisfy the needs of users seeking to maximise the efficiency of routine and specialised UV and visible spectroscopy tasks.
The Model 6400 Visible range unit operates at 320-1100nm.
The Model 6405 UV/Visible range unit operates at 190-1100nm.
Features include:
A customised LCD gives a clear readout of calibration data, sample data and all set-up options.
Specification
Optics
|
Single beam
|
Wavelength range
|
320-1100nm(6400) / 190-1100nm (6405)
|
Resolution
|
0.1nm
|
Accuracy
|
±1.0nm
|
Bandwidth
|
5nm
|
Grating
|
1200 lines/mm
|
Transmittance range
|
0 to 199.9%T
|
Resolution
|
0.1%T
|
Accuracy
|
±1%T@10%T
|
Stray light
|
<0.05%T@340 & 220nm
|
Absorbance range
|
-0.300 to 3.000A
|
Resolution
|
0.001A
|
Accuracy
|
0.005A@1.0A
|
Concentration range
|
-300 to 9999Conc (resolution dependent)
|
Resolution
|
0.001 / 0.01 / 0.1 / 1
|
Jenway Model 6320D 8nm Bandwidth Spectrophotometer
Easy to use
Versatile sampling system
Full interfacing capability
G.L.P. compliant
320-1000nm/8nm SBW
Domed lid enables use with tall sample tubes
The Model 6320D is designed to provide the user with a high quality, low cost measurement system for routine analysis. The 6320D has modes for Absorbance, %T and Concentration measurement. Calibration is performed against a blank (Abs or %T) and a standard or factor for Concentration. Wavelength selection is made electronically via a finely geared stepper motor with a displayed resolution of 1nm.
Features include
A customised LCD gives simultaneous readout of wavelength and photometric result. Error messages, prompts, mode indication and a choice of concentration units are presented in an easily understood format.
Specification
Optics
|
Single beam
|
Wavelength range
|
320-1000nm
|
Resolution
|
1nm
|
Accuracy
|
±2nm
|
Bandwidth
|
8nm
|
Grating
|
1200 lines/mm
|
Transmittance range
|
0 to 199.9%
|
Resolution
|
0.1%
|
Accuracy
|
±1%T
|
Stray light
|
<0.5%T
|
Absorbance range
|
-0.300 to 1.999A
|
Resolution
|
0.001A
|
Concentration range
|
-300 to 1999Conc
|
Resolution
|
0.1/1
|
Units
|
ppm, mg/l, g/l, M, blank
|
Factor
|
0 to 199.9 / 1000 to 9999
|
Jenway Model 6315 8nm Bandwidth Spectrophotometer
Scanning UV/Visible spectrophotometer
Scans in the range of 1998 to 1000nm
Uses pulsed xenon lamp
200 method memory
Quantitation using up to 6 standards
The new Jenway Model 6315 completes the 63 Series product range. Building on the platform of the highly successful 6310, the model 6315 uses a pulsed xenon lamp to extend the wavelength range to the UV region.
The 6315 is an advanced measuring system with modes for Photometrics, Spectrum Scanning, Kinetics, Concentration and Quantitation and will meet the demands of a wide range of applications in areas such clinical, veterinary, environmental and general QC testing.
Specification
Optics
|
Single beam
|
Wavelength range
|
198-1000nm
|
Resolution
|
1nm
|
Accuracy
|
±2nm
|
Bandwidth
|
8nm
|
Transmittance range
|
0 to 199.9%
|
Resolution
|
0.1%
|
Accuracy
|
±1%T
|
Absorbance range
|
-0.300 to 1.999A
|
Resolution
|
0.001A
|
Concentration range
|
-300 to 1999Conc
|
Selectable resolution
|
1/0.1/0.01/0.001
|
Calibration
|
Blank with a single standard or factor
|
Memory
|
50 methods
|
Jenway Model 6310 8nm Bandwidth Spectrophotometer
Photometric measurements in Absorbance and Transmittance
Concentration measurement by direct factor entry or against blank and standard
Quantitation using up to 6 standards - with curve correction and correlation coefficient
Kinetics with real time graphical display of sample and standard runs
Spectrum - scanning any range from 320-1000nm
Store up to 50 methods in each mode
An advanced measuring system with modes for Photometrics, Concentration, Quantitation, Kinetics and Scanning. The 6310 will meet the demands of a wide range of applications, especially those in the clinical, veterinary, environmental, general QC and performance testing areas.
Features include:
With a memory capacity of 50 methods for each mode, the fully open operating system ensures compatibility with reagent kits from most manufacturers, as well as enabling full customisation to the operator's choice of chemistries and operating procedures.
Specification
Optics
|
Single beam
|
Wavelength range
|
320-1000nm
|
Resolution
|
1nm
|
Accuracy
|
±2nm
|
Bandwidth
|
8nm
|
Transmittance range
|
0 to 199.9%
|
Resolution
|
0.1%
|
Accuracy
|
±1%T
|
Absorbance range
|
-0.300 to 1.999A
|
Resolution
|
0.001A
|
Concentration range
|
-300 to 1999Conc
|
Selectable resolution
|
1/0.1/0.01/0.001
|
Calibration
|
Blank with a single standard or factor
|
Memory
|
50 methods
|
Jenway Model 6305 6nm Bandwidth Spectrophotometer
Non-scanning
6nm bandwidth over UV range
Xenon lamp source with extended life
Self calibrating lamp at 3 wavelengths
Full interfacing capability
The Model 6305 is designed to provide the user with a high quality, low cost measurement system for routine analysis.
Features include:
A customised LCD gives simultaneous readout of wavelength and photometric result. Error messages, prompts, mode indication and a choice of concentration units are presented in an easily understood format.
Simple keypad layout and operating protocols ensure reliable operation by unfamiliar users.
Specification
Optics
|
Single beam
|
Wavelength range
|
198-1000nm
|
Resolution
|
1nm
|
Accuracy
|
±2nm
|
Bandwidth
|
6nm over UV range
|
Grating
|
1200 lines/mm
|
Transmittance range
|
0 to 199.9%
|
Resolution
|
0.1%
|
Accuracy
|
±1%T
|
Stray light
|
<0.5%T @ 340 and 220nm
|
Absorbance range
|
-0.300 to 1.999A
|
Resolution
|
0.001A
|
Concentration range
|
-300 to 1999Conc
|
Resolution
|
0.1/1
|
Units
|
ppm, mg/l, g/l, M, blank
|
Factor
|
0 to 199.9 / 1000 to 9999
|
Jenway Model 6300 8nm Bandwidth Spectrophotometer
Easy to use
Versatile sampling system
Full interfacing capability
G.L.P. compliant
320-1000nm/8nm SBW
Now includes free PC Software
The Model 6300 is designed to provide the user with a high quality, easy to use measurement system for routine analysis. The 6300 has modes for Absorbance, %T and Concentration measurement. Calibration is performed against a blank (Abs and %T) and a standard or factor for Concentration. Wavelength selection is made electronically via a finely geared stepper motor with a displayed resolution of 1nm.
Features include:
A custom designed LCD gives simultaneous readout of wavelength and photometric result. Error messages, prompts, mode indication and a choice of concentration units are presented in an easily understood format.
Specification
Optics
|
Single beam
|
Wavelength range
|
320-1000nm
|
Resolution
|
1nm
|
Accuracy
|
±2nm
|
Bandwidth
|
8nm
|
Grating
|
1200 lines/mm
|
Transmittance range
|
0 to 199.9%
|
Resolution
|
0.1%
|
Accuracy
|
±1%T
|
Stray light
|
<0.5%T
|
Absorbance range
|
-0.300 to 1.999A
|
Resolution
|
0.001A
|
Concentration range
|
-300 to 1999Conc
|
Resolution
|
0.1/1
|
Units
|
ppm, mg/l, g/l, M, blank
|
Factor
|
0 to 199.9 / 1000 to 9999
|
Genova Life Science Analyser - DNA
|
Immediate answers to DNA purity
|
|
Pre-programmed for user selectable absorbance ratios
|
|
Direct readout of dsDNA, ssDNA, RNA and Oligo purity
|
|
Purity scan mode
|
|
|
The Genova is designed for the scientist whose primary interest is the study of DNA and proteins. Operation is simple and quick, with all routinely used DNA calculations being pre-programmed into the product. The Genova employs a precision built diffraction grating to select wavelengths and narrow bandwidth, thus avoiding the limited capability of filter based units. Three independent wavelength calibrations are performed during the start-up protocol to guarantee optimum confidence in results and to satisfy G.L.P. procedures.
|
Optimised for low volume analysis the determination of DNA levels as low as 70ng with sample volumes as low as 20µl is possible using the capillary sampling accessory. The Genova will automatically calculate ratios at 260/280 or 260/230 with an optional subtraction of a third wavelength (typically 320nm). Alternatively, pre-programmed factors allow direct readings of ssDNA, dsDNA, RNA and Oligonucleotides.
|
Standard pre-programmed parameters for B.C.A, Bradford, Biuret, Lowry and direct measurement
|
|
Storage of calibration curves
|
|
Versatile open architecture that allows other wavelengths and accessories for other assays to be performed
|
|
The on-board software allows all protein methodologies to be optimised and run on the Genova with a minimum of set-up time. These methodologies can then be viewed on the display for easy interpretation of linearity of response. The Genova has the versatility to change these parameters easily for the scientist who wants to optimise their analysis with different wavelength, curve or constant.
Jenway Fluorimeter Filters
There are 3 types of filter for the Jenway fluorimeters.
The bandpass filters are ideal as excitation filters as they allow only the light between the specified wavelengths through to the sample. For example, UG1 allows all the light between 320 and 380nm through and excludes the light below 320nm and above 380nm.
The cut-off and interference filters are normally used as the emission filters where a much narrower range of wavelengths is required. The cut-off filters block all light below the specified wavelength and the interference filters allow the specified wavelength and light ±5nm of this through to the sample.
Bandpass Filters
Part Code |
Description |
627 126 |
UG1, 320 to 380nm bandpass filter |
627 124 |
BG28, 380 to 500nm bandpass filter |
627 125 |
VG9, 480 to 580nm bandpass filter |
Cut-Off Filters
Part Code |
Description |
627 131 |
Glass, 305nm cut–off filter |
627 130 |
Kodak 2B, 395nm cut–off filter |
627 129 |
Kodak 8, 475nm cut–off filter |
627 128 |
Ilford 201, 545nm cut–off filter |
627 127 |
Kodak 29, 610nm cut–off filter |
Interference Filters
Part Code |
Wavelength |
Part Code |
Wavelength |
627 141 |
250nm |
627 167 |
460nm |
627 132 |
254nm |
627 136 |
470nm |
627 142 |
260nm |
627 168 |
480nm |
627 143 |
265nm |
627 169 |
490nm |
627 144 |
270nm |
627 170 |
500nm |
627 145 |
280nm |
627 171 |
510nm |
627 146 |
290nm |
627 137 |
515nm |
627 147 |
295nm |
627 172 |
520nm |
627 148 |
300nm |
627 173 |
530nm |
627 149 |
305nm |
627 174 |
532nm |
627 150 |
310nm |
627 175 |
540nm |
627 151 |
313nm |
627 176 |
546nm |
627 152 |
320nm |
627 177 |
550nm |
627 153 |
326nm |
627 178 |
560nm |
627 154 |
330nm |
627 179 |
570nm |
627 155 |
334nm |
627 180 |
577nm |
627 156 |
337nm |
627 181 |
580nm |
627 133 |
340nm |
627 182 |
590nm |
627 140 |
350nm |
627 183 |
600nm |
627 157 |
360nm |
627 184 |
610nm |
627 138 |
365nm |
627 185 |
620nm |
627 158 |
370nm |
627 186 |
630nm |
627 134 |
380nm |
627 187 |
633nm |
627 159 |
390nm |
627 188 |
640nm |
627 135 |
400nm |
627 189 |
650nm |
627 160 |
405nm |
627 190 |
656nm |
627 161 |
410nm |
627 191 |
660nm |
627 162 |
415nm |
627 192 |
670nm |
627 163 |
420nm |
627 193 |
680nm |
627 164 |
430nm |
627 194 |
690nm |
627 165 |
436nm |
627 195 |
694nm |
627 166 |
440nm |
627 196 |
700nm |
627 139 |
450nm |
Fluorometers - Jenway
|
62 Series Fluorometers
• High quality optics: pulsed xenon lamp and Total Energy Transfer (TET)
• Intelligent Filter Modules ensure correct filters are fitted for selected method
• Intuitive programming allows fast program creation
• Raw fluorescence or concentration values options
• Standard curve and kinetic functions
• Heated sample holder and sipper pump accessories
• Compatible with DataWay PC software
Jenway offers three Fluorometer models to cover a wide range of applications. The 6280 model is ideal for the most sensitive determinations with emission wavelengths up to 650nm. When higher emission wavelengths are required the 6285 with its red-enhanced detector is the unit of choice. For less sensitive applications and a broader wavelength range up to 1100nm the low cost 6270 unit is more
suitable.
With press-to-read operation and Total Energy Transfer (TET) technology the output of the high-energy xenon lamp is maximised and its expected life extended so that it should never need replacing within the normal lifetime of the unit. The high quality optics are complemented by the Intelligent Filter Modules (IFM) that are identified by the unit, generating error messages should the wrong filters be fitted or their positions be incorrect.
Each model offers intuitive operation with a user interface based on logical menus that can be navigated from the simple keypad. Up to 20 methods can be created without restriction and saved for future use. They can also be locked against accidental change by password entry. The permanent time and date tag on every stored reading supports Good Laboratory Practice, while calibration reminders and operator identity can also be entered to support conformance and traceability of results.
All models are powered from an external, universal mains adapter suitable for use from 90V to 230V, while the 12V DC input enables use in vehicles or from suitable battery packs.
Technical Information
Model: |
6270 |
6280 |
6285 |
Wavelength range |
190 to 1100nm |
190 to 650nm |
190 to 850nm |
Sensitivity1 |
1µg/ml |
<1ng/ml |
<1ng/ml |
Dynamic range1 |
5.2x104 |
5.2x106 |
5.2x106 |
Detector |
Photodiode |
PMT2 |
PMT2 |
Wavelength selection |
Intelligent Filter Modules (IFM) |
Light source |
Pulsed Xenon lamp with press-to-read operation |
Expected life of lamp |
No replacement required in normal operation |
Raw fluorescence readings |
Yes |
Concentration standard curve |
Blank + up to 6 standards |
Kinetics, timed option |
In both raw fluorescence and concentration modes |
Kinetics options |
1 reading every 3 to 999 seconds |
No. methods stored |
20 |
No. results stored |
100 per method |
GLP |
Method lock with password access. Time and date stamped results. Last calibration date and time stored. Calibration interval set. Calibration due reminder. User ID |
Outputs |
RS232 |
PC software |
Compatible with DataWay (option) |
Sample handling |
10mm square cuvette holder (standard). Heated sample holder (option). Sipper pump (option) |
Power supply |
90 to 230V universal mains adapter 12V DC input |
Size (w x d x h) |
365 x 272 x 160mm |
Weight |
6kg |
1 Using quinine sulphate
2 Photomultiplier tube |
|
Flame Photometers - Jenway
|
PFP7 Industrial Flame Photometer
• Designed for industrial analysis
• Supplied with Na, K, Li, Ba and Ca filters
• Low temperature, single channel
• Flame failure safety system
• Operates with propane, butane, natural gas or LPG
The PFP7 is a low temperature, single channel flame photometer that is designed for the routine determination of sodium, potassium, calcium, barium and lithium concentrations. The flame failure safety system makes these products ideal for use in industrial and educational environments. The use of fine and coarse sensitivity controls allows for accurate measurements each and every time.
PFP7/C Clinical Flame Photometer
• Designed for clinical analysis
• Supplied with Na, K and Li filters
• Low temperature, single channel
• Flame failure safety system
• Operates with propane, butane, natural gas or LPG
The PFP7/C is a low temperature, single channel flame photometer that is specifically designed for use in clinical applications for the determination of sodium, potassium and lithium. The in-built lineariser circuitry of the PFP7/C enables readings of both sodium and potassium to be displayed directly in mmol/l. The series 7 diluter is available for use with the PFP7/C to enable serum samples to be diluted efficiently and accurately to the required ratios.
Technical Information
Model: |
PFP7 |
PFP7/C |
Range: |
0 to 199.9ppm |
120 to 160mmol/l Na
0 to 10.0mmol/l K |
Limits of detection: |
Na 0.2ppm
K 0.2ppm
Li 0.25ppm
Ca 15ppm
Ba 30ppm |
Na 0.2ppm
K 0.2ppm
Li 0.25ppm |
Reproducibility: |
<1% coefficient of variation for 20
consecutive samples using 10ppm Na set to read 50 |
<1% coefficient of variation for 20 consecutive samples using 10ppm Na set to read 50 |
Linearity: |
< 2% error when 3ppm Na/K and 5ppm Li are set to read 100 |
< 2% error when 3ppm Na/K and 5ppm Li are set to read 100 |
Stability: |
< 2% drift over 5min when continuously aspirating 10ppm sample set to 50.0 |
< 2% drift over 5min when continuously aspirating 10ppm sample set to 50.0 |
Specificity |
Interference from Na/K and Li equal in concentration to test element will be <0.5% |
Interference from Na/K and Li equal in concentration to test element will be <0.5% |
Recorder output: |
Nominal 1.00V for a reading of 100.0 |
Nominal 1.00V for a reading of 100.0 |
Services: |
Electrical: |
90-125V or 190-250V @50/60Hz |
90-125V or 190-250V @50/60Hz |
Air: |
Moisture and oil free, 6 litre/min @ 14psi |
Moisture and oil free, 6 litre/min @ 14psi |
Fuel: |
Propane, butane, natural gas or LPG |
Propane, butane, natural gas or LPG |
Size (w x d x h): |
420 x 360 x 300mm |
420 x 360 x 300mm |
Weight: |
8kg |
8kg
|
|
Spectrophotometers - Jenway
|
?Jenway are proud to announce the launch of a new double beam spectrophotometer – Model 6850. This is the first spectrophotometer in the Jenway range with a variable spectral bandwidth, providing a very flexible platform for a wide variety of quality control, pharmaceutical, biochemical and clinical applications. The 6850 provides research level performance at a low price point.
This versatile spectrophotometer has an integrated user interface for fast and intuitive local control. The 6850 offers multiple measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, quantitation, kinetics and DNA and protein analysis.
Model 6850 covers the UV/visible wavelength range from 190 to 1100nm with a user selectable spectral bandwidth of 0.5nm, 1nm, 2nm, 4nm or 5nm providing flexibility whilst ensuring compliance to European Pharmacopeia requirements.
An integrated user interface provides full control of the instrument so there is no need to buy a PC to run the spectrophotometer. However, Jenway Prism PC control software is included as standard, introducing functionality such as greater data storage and additional post-measurement tools..
Technical Information
Model |
6850 |
Wavelength range |
190 to 1100nm |
Wavelength resolution |
0.1nm |
Wavelength accuracy |
± 0.3nm (at 0.5 and 1nm bandwidth) ± 0.5nm (at 2, 4 and 5nm bandwidth) |
Wavelength reproducibility |
±0.2nm |
Spectral bandwidth |
Variable 0.5, 1, 2, 4, 5nm |
Photometric range |
–0.3 to 3.0A 0 to 200%T |
Photometric accuracy |
± 0.002A (0-0.5A) ±0.3%T (0-100%T) |
Photometric reproducibility |
±0.001 Abs (0 to 0.5 Abs) ±0.002 Abs (0.5 to 1.0 Abs)0.15%T (0-100%T) |
Resolution |
0.1%T, 0.001A |
Stray light |
<0.05%T at 220 and 360nm |
Noise |
0.0005A |
Stability |
± 0.001A/h at 500nm after 15 min warm up |
Multi–wavelength |
Up to 10 wavelengths, up to 20 wavelengths with PC software |
Calculations |
Ratio, difference, formulae with factors |
Spectrum range |
Any range between 190 and 1100nm |
Scan speed |
100 to 2000nm/min |
Scan interval |
0.1, 0.2, 0.5, 1, 2 or 5nm |
Analysis |
Auto peaks and valleys, zoom, Addition, subtraction, peak ratios, smoothing, area under curve,
wavelength table, derivatives, overlay with PC software |
Kinetics |
Up to 12 hours with time intervals of 0.1, 0.2, 0.5, 1, 2, 5, 10 or 30 seconds |
Analysis |
Slope and formula of line of best fit between any two points |
Quantitation points |
Up to 3 wavelengths |
Quantitation Calibration |
Blank with up to 10 standards or factor |
Concentration range |
0–99999 |
Calibration |
Blank with standards or factor |
DNA |
DNA Ratio, concentration, A320 correction. |
Light source |
Tungsten halogen and Deuterium lamps |
Lamp changeover |
325 to 370nm selectable |
Outputs |
USB and parallel |
Operating system: |
Windows 2000, XP, Vista, Windows 7 |
Electrical supply |
120VA, 220/110V, 50/60Hz |
Size (w x d x h) |
600 x 450 x 200mm |
Weight |
22kg |
|
Spectrophotometers - Jenway
|
?6800 Double-Beam Spectrophotometer
• Double beam spectrophotometer with highly stable optics
• 1.5nm spectral bandwidth
• Jenway Flight Deck software included as standard
• Now available with IQ/OQ documentation
With the 6800 Jenway introduces the first double beam spectrophotometer to the range. The highly stable optics and 1.5nm spectral bandwidth ensures high resolution and accuracy on every measurement. The Jenway Flight Deck software offers modes for all common measurement methods: photometrics and multi-wavelength, spectrum scanning, time scan and kinetics, quantitation, DNA/RNA and protein measurements. With extensive post-measurement tools and easy export to Excel® the 6800 double beam spectrophotometer ensures that all results are presented exactly to your requirements.
The 6800 is now available to order with IQ/OQ documentation. IQ/OQ is the process of verifying and validating that the instrument is installed correctly and conforms to its specification. This documentation is an important component of the quality management system.
Technical Information
Model |
6800 |
Wavelength range |
190 to 1100nm |
Wavelength resolution |
0.1nm |
Wavelength accuracy |
±0.3nm |
Wavelength repeatability |
±0.1nm |
Spectral bandwidth |
1.5nm |
Transmittance |
0 to 600%T |
Absorbance |
–3.0000 to 3.0000A |
Accuracy |
±0.3%T, ±0.002A at 0 to 0.5A, ±0.004A at 0.5 to 1.0A, ±0.008A at 1.0 to 2.0A |
Reproducibility |
±0.15%T, ±0.001A at 0 to 0.5A, ±0.002A at 0.5 to 1.0A, ±0.004A at 1.0 to 2.0A |
Resolution |
0.01%T, 0.0001A |
Stray light |
<0.05%T at 220 and 340nm |
Noise |
0.0003A |
Stability |
±0.0003A/h after 2h |
Multi–wavelength |
Up to 6 wavelengths |
Calculations |
Ratio, difference, formulae with factors |
Spectrum range |
Any range between 190 and 1100nm |
Scan speed |
10 to 3600nm/min (8 speed settings) |
Scan interval |
0.5, 1, 2 or 5nm, dependent on scan speed |
Analysis |
Auto peaks and valleys, zoom, addition, subtraction, peak ratios, smoothing, area under curve, wavelength table, derivatives, overlay |
Time scan and Kinetics |
Between 30 to 99999 seconds |
Analysis |
Slope and formula of line of best fit between any two points |
Quantitation points |
Up to 3 wavelengths |
Concentration range |
0–99999 |
Calibration |
Blank with standards or factor |
DNA/RNA and Protein |
DNA/RNA Ratio, concentration, A320correction. Protein; Bradford, Lowry, BCA, direct UV |
Light source |
Tungsten halogen and Deuterium lamps |
Lamp changeover |
325 to 370nm selec table |
Outputs |
RS232 |
Operating system: |
CPU: 1GHz Memory: 256Mb Hard disk: 500Mb |
Power |
200VA |
Size (w x d x h) |
540 x 560 x 235mm |
Weight |
27kg
|
|
Spectrophotometers - Jenway
|
?Genova Life Science Spectrophotometer
• Pre-programmed for DNA/RNA analysis
• DNA purity scan mode
• Pre-loaded protein concentration determination methods
• Standard spectrophotometer functions
The Genova allows the measurement of DNA concentrations and purity ratios using the wavelengths recorded at 260 and 280nm or 260 and 230nm with optional correction at a third wavelength. The purity scan gives a clear, graphic display of DNA purity. This allows any shifted or distorted peaks due to interfering molecules to be identified. The Genova also contains five pre-programmed methods for the Bradford, Lowry, Biuret, Bicinchonininc acid (BCA) and Direct UV techniques. In all cases the standard procedures may be modified by the user or run as programmed.
Technical Information
Model |
Genova |
Wavelength range |
198 to 1000nm |
Wavelength resolution |
1nm |
Wavelength accuracy |
±2nm |
Wavelength repeatability |
±0.5nm |
Spectral bandwidth |
8nm, 5nm typical at 270nm |
Transmittance |
0 to 199.9%T |
Absorbance |
–0.300 to 1.999A |
Photometrics accuracy |
±1%T at 10%T |
Resolution |
0.1%T, 0.001A |
Stray light |
<0.5%T at 220 and 340nm |
Noise |
<0.001A at 0A at 400nm |
Stability |
<0.002A/h after 30 minutes |
Concentration range |
–300 to 9999 |
Concentration resolution |
Selectable 1, 0.1, 0.01 or 0.001 |
Units |
ppm, mg/l, g/l, M, %, µg/l, µg/ml, mg/ml, ng/ml, blank (mode specific) |
Factor |
0 to 199.9, 1000 to 9999 |
Spectrum range |
Survey scan 50nm either side of set wavelength (250–950nm) |
Scan interval |
1nm |
Analysis |
Absorbance and wavelength of peak |
GLP |
Real time clock and calendar, Operator ID. Supervisor security (locks all set up parameters). Method display lock |
Light source |
Xenon lamp |
Outputs |
Analogue and RS232 |
Power |
<50W |
Size (w x d x h) |
365 x 272 x 160mm |
Weight |
6kg
|
|
Chloride meter Jenway PCLM3 supplied with buffer, gelatin, chloride standard, 3 silver electrodes, 2 silver anodes, electrode polish, glass beaker, stirrer and tweezers (230V/50Hz)
• For clinical or industrial applications
• Uses proven coulometric titration principle
• Three sample volumes: 20 and 100µl for clinical and 500µl for industrial
• Simple to operate
• Fast reliable results
• Automatic indication when reagent replacement or electrode cleaning is required
The PCLM3 chloride meter can be used to determine chloride concentrations in numerous types of samples. Biological samples such as serum, plasma, urine, sweat and cerebrospinal fluid are commonly tested. Other samples can be tested provided they are of low ionic strength, neutral pH, have low levels of dissolved solids, low solid matter and are free from silver halides and other components which may react with silver.
Technical Specification
Clinical Meter
Parameter |
Clinical Meter |
Range |
10 to 299mmol/l |
Sample volume |
20µl or 100µl |
Reproducibility |
±1% for 100µl sample at 100mmol/l, ±1.5% for 20µl sample at 100mmol/l |
Linearity |
<±1mmol/l or ±1% of concentration value (whichever is the greater) |
Power |
230, 50Hz |
Size (w x d x h) |
240 x 215 x 160mm |
Weight |
3.1kg |
Industrial Meter
Parameter |
Industrial Meter |
Range |
10 to 999mg/l |
Sample volume |
500µl |
Reproducibility |
±3mg/l |
Linearity |
±3mg/l or 1% (whichever is the greater) |
Power |
230, 50Hz |
Size (w x d x h) |
240 x 215 x 160mm |
Weight |
3.1kg |
Ordering Information
Part Code |
Description |
504 043 |
PCLM3 clinical chloride meter supplied with buffer, gelatin, clinical chloride standard, 3 silver electrodes, 2 silver anodes, electrode polish, glass beaker, stirrer and tweezers (230V/50Hz) |
504 044 |
PCLM3 industrial chloride meter supplied with buffer, gelatin, industrial chloride standard, 3 silver electrodes, 2 silver anodes, electrode polish, glass beaker, stirrer and tweezers (230V/50Hz) |
Consumables
Part Code |
Description |
504 053 |
Pack of 3 silver anodes |
504 052 |
Pack of 3 silver electrodes (1 cathode, 2 detectors) |
060 028 |
Electrode polish |
025 011 |
Acid buffer solution (500ml) |
025 013 |
Chloride standard, clinical, 100mmol/l (180ml) |
025 014 |
Chloride standard, industrial, 200mg/l (180ml) |
060 029 |
Stirrer bars (pack of 10) |
024 018 |
Glass beaker |
025 012 |
Gelatin (30ml) |
025 195
Colorimeters - Jenway
|
6051 Bench Colorimeter
• Wide wavelength range from 400 to 710nm
• Ideal for routine and educational use
• Easy to use and conventional style controls
• Sample flexibility with many size options
• Mains or battery operated
The 6051 is a general purpose colorimeter, equipped with easy-to-use conventional style controls, making it ideal for routine and educational use.
Standard 10mm square cuvettes, semi-micro volume cuvettes, flowthrough or pour in/suck out cells can all be used with the standard sample holder. Excellent sampling flexibility is achieved through the optional cell holder assemblies, allowing the use of 10, 20, and 40mm cells, whilst multiple sampling handling is possible with the four cell carriage. For temperature-dependent measurements a heated cell block is available.
Technical Information
Model: |
6051 |
Wavelength range: |
400 to 710nm |
Wavelength selection : |
8 in-built gelatin filters: 430, 470, 490, 520, 540, 580, 600 and 710nm |
Measurement ranges: |
0-100%T
0-1.50Abs
0.1 to 1000 Conc |
Resolution: |
1%T, 0.01Abs, 0.1 to 1 Conc |
Bandwidth: |
Typically 40nm |
Blank drift: |
2%/hr after 15 minute warm-up |
Photometric linearity: |
1%T |
Light source: |
Tungsten filament lamp |
Output: |
Analogue, 10mV per digit |
Power: |
230V, 50Hz |
Size (l x w x d): |
300 x 355 x 120mm |
Weight: |
3kg
|
|
|
Combined acid buffer (500ml)
|