LAMINAR DOWN-FLOW CABINET CLASS 100 |
|
|
ANOTHER STEP FOR PRODUCT AND OPERATOR PROTECTION WHEN SPACE IS A PREMIUM.
The special design of the AURA MINI allows safe manipulation of sterile products, with an inward air barrier which increases operator safety. Outward barrier mode and Active mode PCR versions are available (with UV).
The Aura MINI has been designed and tested for the following applications:
> Sterility testing
> Cell culture
> Molecular biology
> Drug preparation
> Assembly of optical and electronics components.
> PCR
|
MAIN SPECIFICATIONS |
|
Inflow configuration
Laminar downflow at a constant airspeed of 0.4m/sec Face velocity: >0.45 m/sec Recirculatory mode with 70% recirculated air through main HEPA Filter and 30% exhausted air through high efficiency exhaust filter. This configuration for Class 100 product handling and excellent containment factor and PCR.
Outflow Configuration
Laminar downflow with total exhaust through front opening and double filtration (through high efficiency prefilter and main HEPA filter) of inlet air. This configuration for maximum product protection and Class 100 working area.
All configurations
Filters types: Main filter: HEPA (High Efficiency Particulate Airfilter) with penetration less than 0.003% for 0.3m particles, tested to BS3928 and conform to DIN24184 Exhaust/Inlet filter: Filtrete type with efficiency higher than 97% on 0.3 micron particles. |
|
> DOP tested
> Conformity to IEC 66.5
> CE marked
> Construction: Epoxy coated mild steel
> Base tray: 304 stainless steel
> Glazing: tempered glass
> Fan: centrifugal with variable speed and thermal cut-out.
> Control panel: soft-touch membrane, on/off switch, elapsed time meter, light switch.
> Lighting: >1.000 Lux
> Noise level <60dB(A)
> HEPA filters manufactured in accordance with MIL-F51068 and BS-3928 with an efficiency higher than 99.999% on 0.3micron particles, DOP tested |
|
|
|
LAMINAR DOWN-FLOW CABINET CLASS 100 |
|
|
AURA S.D.4, SLIDING SASH, SLOPED FRONT CABINET, ENVIRONMENTAL FRIENDLY, PARTIAL-RECIRCULATING DOWN-FLOW CABINET DESIGNED IN ORDER TO ALLOW HIGHLY COMFORTABLE WORKING CONDITIONS.
Main applications for S.D.4 are:
> Manipulation of non-pathogenic material
> Media preparation
> Plant and animal tissue culture
> Sterility tests
> Assembling of optical or microelectronic components
> Food industry (microbiology)
|
MAIN SPECIFICATIONS |
|
This unit works on a recirculatory mode with air being filtered by an HEPA filter with 99.999% efficiency on 0.3µ particles, before entering the work area at a speed of 0.45 m/sec; this ensures a Class 100 environment throughout the work area. Air coming through the front aperture is then mixed with the down-flow air, without affecting the product, and recirculated. 70% of the air is returned to the working area through the main HEPA filter and 30% is exhausted into the environment through an exhaust HEPA filter. This ensures double protection both for the product and for the operator The special sloped front design and the sliding sash ensure comfortable working position and, when needed, a very easy opening and closing of the front window.
Extremely quiet operation: noise level <58dB(A). Side walls and sliding sash in safety tempered glass. Main and exhaust HEPA Filter with 99.999% efficiency on 0.3µ particles DOP tested. Removable perforated work surface and back wall of working area in SS 304 |
|
> Self-calibrating centrifugal motor-blower
> Elapsed time meter for HEPA filter life.
> Soft touch keys on the control panel provide control of the lighting, motor-blower, UV light, solenoid valve and power point.
> Visual and acoustic alarms are provided for fan failure.
> Unique x/y direction sliding sash. This has three positions: 1. fully open 2. standard working height 3. closed: with an air and formaldehyde tight seal.
> Version without HEPA filter in exhaust available.
> Cabinet outer surfaces made of cold rolled steel with paint finish
> Removable, perforated work surface and back wall of internal chamber made of grade 3 stainless steel
> Front sliding window and side panels in tempered glass
> HEPA filter manufactured in accordance with MIL-F51068 and BS-3928, with an efficiency higher than 99.999% on 0.3µ particles, DOP tested.
> Sloped front and sliding sash window for the most comfortable operation
> Œ marked
|
|
|
|
LAMINAR DOWN-FLOW CABINET CLASS 100 |
|
|
LAMINAR DOWN-FLOW WORKSTATION. PROBABLY THE HIGHTEST APF (APERTURE PROTECTION FACTOR) IN ITS CATEGORY FOR THE SAFEST HANDLING OF PRODUCTS.
AVAILABLE WITH EXHAUST HEPA.
The aura VF has been designed and tested for the following applications:
> Manipulation of non pathogens microorganisms
> Animal and plant cell-culture
> Molecular biology
> Drug preparation
> Assembly of optical and electronics components.
|
MAIN SPECIFICATIONS
|
|
Maximum operator, product and environmental protection on Aura VFis obtained with a design identical to the one tipical of biosafety cabinets. The unit works on a recirculatory principle with air passing through the main Hepa filter before entering the working area where Class 100 conditions are obtained Air coming through the front aperture is then mixed with the down-flow air without affecting the product, and recirculated; 30% of it is exhausted into the environment through an exhaust HEPA filter. 70% of this air is finally pushed again through the main HEPA filter. This ensures product manipulation in an environment conforming with Federal standard 209E class 100 and British standard 5295 class B. At the same time the operator and the environment are protected from any possible contaminant present in the working area.
|
|
> Laminar down-flow at a constant airspeed of 0.4m/sec
> Face velocity: 0.45 m/sec
> Recirculatory mode with 70% recirculated air through main hepa filter and 30% exhausted air through high efficiency exhaust filter.
> Microprocessor controlled. Automatic air speed control, low barrier speed alarm, filter clogging alarm, service warning.
> Double plenum with dynamic air-tightness
> Standard Options (included): front closing panel, internal 6Amps socket, vacuum tap.
> Available as single Hepa filter configuration (down-flow main Hepa only), no exhaust Hepa filter.
> Conformity to IEC 66.5
> Œ marked
> HEPA filters manufactured in accordance with MIL-F51068 and BS-3928 with an efficiency higher than 99.999% on 0.3micron particles, DOP tested.
> Construction: epoxy coated mild steel
> Base tray: 304 stainless steel; autoclavable.
> Glazing: tempered glass
> Filters types. Main and exhaust filters: HEPA filters manufactured in accordance with MIL F51068 and BS 3928 with an efficiency higher than 99.999% on 0.3micron particles, DOP tested with penetration less than 0.003% for 0.3 micron particles, tested to BS 3928 and conform to DIN 24184.
> Fan: centrifugal with variable speed and thermal cut-out.
> Control panel: soft-touch membrane, on/off switch, fan switch, elapsed time meter, light switch, visual and audible alarms.
> Lighting: 1.000 lux, fluorescent lights
> Noise level <60dB(A |
|
|
Faster BHG Cabinet
|
MICROPROCESSOR CONTROLLED WITH ELECTRICALLY OPERATED SASH WINDOW
FOREWORD
BHG safety cabinets belong to the latest generation of laminar airflow systems, combining rigid safety requirements with high quality construction.
BHG has been designed as a Class II Biohazard cabinet according to EN-12469.
Therefore it provides vertical laminar airflow with part of the air recirculated via the main HEPA filter whilst the remaining part is discharged through an exhaust HEPA filter. This cabinet is suitable for handling CDC 1-3, DPAG C-B1-B2 etiologic agents, providing operator, product and environmental protection
BHG cabinets are provided with electrically operated, vertically sliding safety glass sash window
APPLICATIONS
BHG cabinets can be used in a wide range of disciplines, as defined in appropriate standards.
Especially suitable for applications such as:
- Microbiology
- Virology
- Haematology
- Cell culture
- Recombinant DNA
- Handling of hazardous agents to human beings or animals as defined in the appropriate international standards.
BENEFITS
- Sophisticated microprocessor based monitoring system
- Sophisticated microprocessor based system of audible and visual alarms alerts the operator if the cabinet does not run in complete safety.
- Self-adjusting system to ensure a constant laminar airflow speed even in the presence of a progressive clogging of the filters.
- The negative pressure plenum "bio-dynamic sealing" ensures that all contaminated particles are kept inside the system and are automatically drawn to the pressure chamber to be captured by the main and exhaust filters.
- The fan system assures that no part of the cabinet is under positive contaminated pressure to the laboratory, thus preserving environment and personnel from bio-contamination risks.
- Access from the front panel for ease of maintenance service.
- Available in one motor (BHG 2004 S) as well as two motors (BHG 2004 D) versions for flexible performance selection in line with the cabinet's use.
- The electrically driven sash window (easily moved up and down by merely p
|
|
BSC-EN 1.2m Cabinet
Microprocessor controlled with double fan
Foreword
BSC-EN safety cabinets belong to the latest generation of laminar airflow systems, combining rigid safety requirements with high quality construction.
BSC-EN has been designed as a Class II Biohazard cabinet according to EN-12469.
Therefore it provides vertical laminar airflow with part of the air recirculated via the main HEPA filter whilst the remaining part is discharged through an exhaust HEPA filter. This cabinet is suitable for handling CDC 1-3, DPAG C-B1-B2 etiologic agents, providing operator, product and environmental protection
Applications
BSC-EN cabinets can be used in a wide range of disciplines, as defined in appropriate standards.
Especially suitable for applications such as:
- Microbiology
- Virology
- Haematology
- Cell culture
- Recombinant DNA
- < >Handling of hazardous agents to human beings or animals as defined in the appropriate international standards. Sophisticated microprocessor based monitoring system
- Sophisticated microprocessor based system of audible and visual alarms alerts the operator if the cabinet does not operate in complete safety.
- Self-adjusting system to ensure a constant laminar airflow speed even in the presence of a progressive clogging of the filters.
- The negative pressure plenum "bio-dynamic sealing" ensures that all contaminated particles are kept inside the system and are automatically drawn to the pressure chamber to be captured and by the main and exhaust filters.
- The fan system assures that no part of the cabinet is under positive contaminated pressure to the laboratory, thus preserving environment and personnel from bio-contamination risks.
- < >Access from the front panel for ease of maintenance service
- Construction: Epoxy powder painted steel for improved strength and resistance to corrosion and atmospheric agent.
- Work Surface : AISI-316 stainless steel completely perforated to ensure flow laminarity and air recycling at the work surface level. Frontal slots in the access area provide air barrier protection preventing any exchange of air between the inside of the cabinet and the environment.
- On request the following work surfaces are available:
- AISI-316 stainless steel perforated work surface in 3, 4, or 6 pieces
- < >AISI-316 stainless steel solid work surface in 1,3, 4, or 6 pieces display of laminar airflow velocity and frontal air barrier velocity
- display of inside and outside temperature
- display of residual lifetime of HEPA filters, U.V. Lamp and charcoal filter (if installed)
- display of total time of cabinet operation
- < >display of power rating factor of the main and exhaust (if installed) motor-blowers. out of range laminar airflow velocity and front air barrier velocity
- front window opened.
- HEPA filters clogging
- UV lamp worn-out (if installed)
- charcoal filter (if installed) saturated
- blackout
- < >signal of other possible malfunctions and relevant remedies. two vacuum or gas connections in the working area are provided, one with manual tap, the other with solenoid valve (on the right-hand side).
- A stainless steel spillage tray beneath the work surface collects spilt liquids.
- A stainless steel front closure panel ensures the sealing of the cabinet for sterilization/fumigation .
- An inlet allows the DOP test of the absolute HEPA filters.
- Electrical socket with protection IP-44 (on the right-hand side)
- < >Maintenance: access to filters, motor-blower/s and control panel by lifting the front panel. UV lamp for sterilization of the work chamber installed onthe front closure, controlled by two timers, one with 0¸3 hours scale (1 minute steps), the other 3 fixed hours.
- Code
- Model
- Useful dimensions mm
- Overall dimensions mm
-
Code
|
Model
|
Useful dimensions mm
|
Overall dimensions mm
|
|
|
W
|
H
|
D
|
W
|
H
|
D
|
O74 600220
|
BSC-EN 2-4
|
1190
|
660
|
580
|
1395
|
1470
|
780
|
Working aperture mm
|
Exhaust duct Æ
|
Temperature rise
|
Volts
Hz
|
Noise
dBA
|
Lighting
lux
|
Vibration
mm rms
|
200
|
200mm
|
<4° C
|
230/50
|
<65
|
>750
|
<0.005
|
BSC-G Class II Cabinets
Foreword
BSC-G safety cabinets belong to the latest generation of laminar airflow systems, combining rigid safety requirements with high quality construction. BSC-G has been designed as a Class II Biohazard cabinet according to EN 12469. Therefore it provides vertical laminar airflow with 70% of the air recirculated via the main HEPA filter whilst the remaining 30% is discharged through an exhaust HEPA filter. This cabinet is suitable for handling CDC 1-3, DPAG C-B1-B2 etiologic agents, providing operator, product and environmental protection. BSC-G cabinets are provided with electrically operated, vertically sliding safety glass sash window
Applications
BSC-G cabinets can be used in a wide range of disciplines.
Especially suitable for applications such as:
-
Microbiology
-
Virology
-
Haematology
-
Cell culture
-
Recombinant DNA
Handling of hazardous agents to human beings or animals as defined in the appropriate international standards. The fan system assures that no part of the cabinet is under positive contaminated pressure to the laboratory, thus preserving environment and personnel from bio-contamination risks. Access from the front panel for ease of maintenance service.
Available in one motor (BSC-G 1) as well as two motors (BSC-G 2) versions for flexible performance selection in line with the cabinet’s use. The electrically driven sash window (easily moved up and down by merely pressing the keys placed on the front panel) can be completely closed or opened to make the operator’s work easier.
Benefits
-
Sophisticated microprocessor based monitoring system
-
Sophisticated microprocessor based system of audible and visual alarms alerts the operator if the cabinet does not operate in complete safety.
-
Self-adjusting system to ensure a constant laminar airflow speed even in the presence of a progressive clogging of the filters.
-
The negative pressure plenum "bio-dynamic sealing" ensures that all contaminated particles are kept inside the system and are automatically drawn to the pressure chamber to be captured and by the main and exhaust filters.
Specifications
Construction: Epoxy powder painted steelfor improved strength and resistance to corrosion and atmospheric agents.
Work Surface
: AISI-316 stainless steel completely perforated to ensure flow laminarity and air recycling at the work surface level. Frontal slots in the access area provide air barrier protection preventing any exchange of air between the inside of the cabinet and the environment.
On request the following work surfaces are available:
Work Chamber: in AISI-304 stainless steel sheet.
Absolute Filters
: HEPA filters, tested with D.O.P. aerosol. Their efficiency, higher than 99,995% MPPS - 0.005% penetration - ensures a performance exceeding the requirements of EN 1822, U.S. Federal Standard 209 e, British Standard 5295, VDI-2083 and AS 1386-1976. The filtration system is designed to provide a barrier of air with minimum average speed over 0.4m/sec. according to EN-12469.
Motor-blower/s: One centrifugal fan (BSC-G I) and two centrifugal fans (BSC-G II), direct driven motors, with protection factor IP-55, controlled by two automatic speed regulators and microprocessor system showing laminar flow and protection barrier work conditions.
Microprocessor based monitoring system: new generation system for controlling the cabinet in a full digital way performs high level control and data processing. The handy and practical keyboard and the rearlit LCD display keep the user constantly informed of the cabinet conditions and operation, in particular:
-
Display of laminar airflow velocity and frontal air barrier velocity
-
Display of inside and outside temperature
-
Display of residual lifetime of HEPA filters, U.V. Lamp and charcoal filter (if installed)
-
Display of total time of cabinet operation
-
Display of power rating factor of the main and exhaust (if installed) motor-blowers.
Alarms for:
out of range laminar airflow velocity and front air barrier velocity front window out of the working position HEPA filters clogging UV lamp worn-out (if installed) charcoal filter (if installed) saturated blackout signal of other possible malfunctions and relevant remedies.
Power Supply
: 230 V, 50Hz, single phase.
Lighting:
fluorescent tubes in built-in housing, placed outside the contaminated area.
Front window
: stratified safety glass. The 3 degrees sloping fronted window optimises the visibility inside the work chamber. When the cabinet is off, the window can be opened to 465 mm maximum or can be completely closed.
Additional Feature
s:
-
Two vacuum or gas connections in the working area are provided, one with manual tap, the other with solenoid valve (on the right-hand side).
-
A stainless steel spillage tray beneath the work surface collects spilt liquids.
-
An inlet allows the DOP test of the absolute HEPA filters.
-
Electrical socket with protection IP-44 (on the right-hand side)
-
Maintenance: access to filters, motor-blower/s and control panel by lifting the front panel.
As option
-
UV lamp for sterilization of the work chamber installed on the front closure panel, controlled by two timers, one with 0¸3 hours scale (1 minute steps), the other 3 fixed hours.
Technical characteristics "BSC-G 1/2"
Code
|
Model
|
Useful dimensions (mm)
|
Overall dimensions (mm)
|
W
|
H
|
D
|
W
|
H
|
D
|
O74 700110
|
BSC-G 1-3
|
885
|
665
|
646
|
1090
|
1470
|
885
|
O74 700120
|
BSC-G 1-4
|
1190
|
665
|
646
|
1395
|
1470
|
885
|
O74 700130
|
BSC-G 1-6
|
1800
|
665
|
646
|
2005
|
1470
|
885
|
O74 700210
|
BSC-G 2-3
|
885
|
665
|
646
|
1090
|
1470
|
885
|
O74 700220
|
BSC-G 2-4
|
1190
|
665
|
646
|
1395
|
1470
|
885
|
O74 700230
|
BSC-G 2-6
|
1800
|
665
|
646
|
2005
|
1470
|
885
|
Working aperture (mm)
|
Exhaust duct Æ
|
Temperature rise
|
Volts
Hz
|
Noise
dBA
|
Lighting
lux
|
Vibration
mm rms
|
200
|
200mm
|
<4° C
|
230/50
|
<65
|
>750
|
<0.005
|
Accessories
Code
|
Description
|
O74 700920
|
Epoxy powder painted modular stand for BSC-G-4
|
O74 700500
|
UV Lamp for BSC-G
|
O74 702020
|
Exhaust charcoal filter with housing for BSC-G
|
O74 799521
|
Additional exhaust HEPA filter with housing for BSC-G
|
O74 799510
|
Anti-blowback valve
|
O74 702050
|
Additional service connection for electrical power
|
O74 702060
|
Additional service connection for gas/vacuum (manual tap)
|
BSC-EN 2000 Cabinets - Faster
|
Microprocessor Controlled With Single
or Double Fan
Foreword
BSC-EN 2000 safety cabinets belong to the latest generation of laminar airflow systems, combining rigid safety requirements with high quality construction.
BSC-EN 2000 has been designed as a Class II Biohazard cabinet according to EN-12469.
Therefore it provides vertical laminar airflow with part of the air recirculated via the main HEPA filter whilst the remaining part is discharged through an exhaust HEPA filter. This cabinet is suitable for handling CDC 1-3, DPAG C-B1-B2 etiologic agents, providing operator, product and environmental protection
Applications
BSC-EN 2000 cabinets can be used in a wide range of disciplines, as defined in appropriate standards.
Especially suitable for applications such as:
Benefits
-
Sophisticated microprocessor based monitoring system
-
Sophisticated microprocessor based system of audible and visual alarms alerts the operator if the cabinet does not operate in complete safety.
-
Self-adjusting system to ensure a constant laminar airflow speed even in the presence of a progressive clogging of the filters.
-
The negative pressure plenum "bio-dynamic sealing" ensures that all contaminated particles are kept inside the system and are automatically drawn to the pressure chamber to be captured and by the main and exhaust filters.
-
The fan system assures that no part of the cabinet is under positive contaminated pressure to the laboratory, thus preserving environment and personnel from bio-contamination risks.
-
Access from the front panel for ease of maintenance service.
-
Available in one motor (BSC-EN 2000 S) as well as two motors (BSC-EN 2000 D) versions for flexible performance selection in line with the cabinet's use.
Specifications
Construction: Epoxy powder painted steel for improved strength and resistance to corrosion and atmospheric agents.
Work Surface : AISI-316 stainless steel completely perforated to ensure flow laminarity and air recycling at the work surface level. Frontal slots in the access area provide air barrier protection preventing any exchange of air between the inside of the cabinet and the environment.
On request the following work surfaces are available:
-
AISI-316 stainless steel perforated work surface in 3, 4, or 6 pieces
-
AISI-316 stainless steel solid work surface in 1,3, 4, or 6 pieces
Work Chamber: in AISI-304 stainless steel sheet.
Absolute Filter : HEPA filters, tested with D.O.P. aerosol. Their efficiency, higher than 99,995%MPPS - 0.005% penetration - ensures a performance exceeding the requirements ofEN 1822, U.S. Federal Standard 209 e, British Standard 5295, VDI-2083 and AS 1386-1976.
The filtration system is designed to provide a barrier of air with minimum average speed over 0.4m/sec. according to EN-12469.
Motor-blower/s: One centrifugal fan (BH-EN 2000 S) and two centrifugal fans (BH-EN 2000 D), direct driven motors, with protection factor IP-55, controlled by two automatic speed regulators and microprocessor system showing laminar flow and protection barrier work conditions.
Microprocessor based monitoring system: new generation system for controlling the cabinet in a full digital way performs high level control and data processing.
The handy and practical keyboard and the rearlit LCD display keep the user constantly informed of the cabinet conditions and operation, in particular:
-
display of laminar airflow velocity and frontal air barrier velocity
-
display of inside and outside temperature
-
display of residual lifetime of HEPA filters, U.V. Lamp and charcoal filter (if installed)
-
display of total time of cabinet operation
-
display of power rating factor of the main and exhaust (if installed) motor-blowers.
Alarms for:
-
out of range laminar airflow velocity and front air barrier velocity
-
front window opened.
-
HEPA filters clogging
-
UV lamp worn-out (if installed)
-
charcoal filter (if installed) saturated
-
blackout
-
signal of other possible malfunctions and relevant remedies.
Power Supply : 230V, 50Hz, single phase.
Lighting: fluorescent tubes in built-in housing, placed outside the contaminated area.
Front window : Stratified safety glass, to give ease of access for large items.
It is provided with gas spring to keep it open during maintenance or sanitization operations.
Additional Features:
-
two vacuum or gas connections in the working area are provided, one with manual tap, the other with solenoid valve (on the right-hand side).
-
A stainless steel spillage tray beneath the work surface collects spilt liquids.
-
A stainless steel front closure panel ensures the sealing of the cabinet for sterilization/fumigation .
-
An inlet allows the DOP test of the absolute HEPA filters.
-
Electrical socket with protection IP-44 (on the right-hand side)
-
Maintenance: access to filters, motor-blower/s and control panel by lifting the front panel.
As Option:
-
UV lamp for sterilization of the work chamber installed onthe front closure, controlled by two timers, one with 0¸3 hours scale (1 minute steps), the other 3 fixed hours.
Data:
Code
|
Model
|
Useful Dimensions (mm)
|
Overall Dimensions (mm)
|
Power (Kw)
|
Weight (Kg)
|
W
|
H
|
D
|
W
|
H
|
D
|
F74 600220
|
BH-EN 2004-D
|
1190
|
660
|
580
|
1395
|
1470
|
785
|
1.1
|
218
|
Front Aperture
|
Temperature rise
|
Exhaust duct
|
Noise level
|
Lighting
|
Vibrations
|
200 mm
|
< 4° C
|
Æ 200 mm
|
< 59 dBA
|
> 1000 lux
|
< 0,005 mm RMS |
|
|
|
BIOHAZARD
CLASS II
MICROBIOLOGICAL SAFETY CABINET CLASS II (Type A) WITH MICROPROCESSOR CONTROL AND DUAL EXAUST HEPA FILTER - Certified BS 5726 (1992)
Class II microbiological safety cabinet for handling low to moderate risk-hazarded agents; personnel protection, product protection and ambient safety from exposure to biological agents.
|
MAIN SPECIFICATIONS |
|
The AURA 2000 BS is a Class II Microbiological Safety Cabinet Type A. 70% of the HEPA filtered air is therefore recirculated with the remaining 30% being expelled through two online dedicated exhaust HEPA filters as recommended by BS 5726 for recirculating cabinets. (No ducting required). The cabinet is used to reduce the exposure of both product and personnel to airbone biological agents. The AURA 2000 B.S. has a new, microprocessore based airflow control system. A microprocessor provides automatic control of the airflow throughout the whole usable life of the HEPA filters.
The microprocessor based module contains the alarm system which warns the operator when recirculated and exhaust airflow deviate from the fixed operation range and when the front window is not firmly closed. The soft-touch keyboard together with the alphanumeric display, bargraphs and pilot lamps give the operators a full control and monitoring of all functions. Laminar flow and face velocities are permanently displayed while the UV lamp, cabinet conditions, filters, run hours and blackout events are displayed by touching the multifunction keys.
The microprocessor module also controls tha lights, electrical power outlet, gas solenoid valve and 24 hours clock with UV timer function.
All of the contaminated plenum inside the cabinet is surrounded by a negative pressure to prevent contaminated air leaks as required by the latest international standard. |
Removable work surface. Microprocessor based control. Electrical equipment according to IEC 1010-International Standards and EMC directives.
Alarm for ventilation failure. Automatic control of the fan speed. Stainless steel grade 3 work chamber. Conformity to CE machine directives |
> The microprocessor control module is located inside the front panel in a non contaminated zone.
> The air flow control system provides a constant air flow until the pressure across the HEPA filter emissing in reaches 400 Pa.
> The digital display and air velocity bargraph indicators give a continuous monitoring of the air flow conditions.
> Visible and audible alarms are activated when the laminar and exhaust air flow rates fall or exceed the fixed thresholds and when the front window is not closed securely.
> Soft touch keys on the control panel provide of the lighting, UV lamp, electrical power outlet and the solenoid valve which regulates the gas supply line.
> Two online exaust hepa filters
> Two dedicated D.O.P. ports
> Variable speed centrifugal fan with built-in thermal cut-out.
> Electrical equipment according to IEC 1010-1 International Standards AND emc directives.
> Lighting > 800 lux. - Noise level < 58 db (A).
> Cabinet outer surfaces made of rolled steel with paint finish.
> Inner chamber made of grade 3 stainless steel with radiussed corners and full access to exposed surfaces for ease of cleaning.
> Removable work surface made of grade 3 stainless steel with perforated work area and shaped front grille to prevent obstruction of the safety air barrier intake. -
> Sump made of grade 3 stainless steel, with coved corners for easy removal of spilt liquids.
> HEPA filters manufactured in accordance with MIL-F51068 and BS-3928 with an efficiency higher than 99.999% on 0.3micron particles, DOP tested. |
|
|
AURA 2000 BS |
Work Chamber Dimensions
(lxpxh)
|
1185 x 580 x 670 mm |
Overall Dimensions (lxpxh)
|
1450 x 785 x 1440 mm |
Weight
|
225 Kg |
Power Supply
|
230 volt - 50 hz |
Power Requirements
|
2,2 kw |
Noise level |
< 59 dB(A) |
|
|
|
CLASS II BIOSAFETY CABINET
|
|
|
Double fan, electronic controlled Biosafety Cabinet Class II type A/B3 convertible for highest operator and environmental protection, with a total product protection
The double fan configuration ensures added safety in case of emergencies. Manufactured in compliance with the main European standards |
MAIN SPECIFICATIONS |
|
BIOAIR Class II biosafety cabinets AURA B are designed to fully comply with the main European standards (BS5726, DIN 12950 Teil 10). Based on the 2 fan configuration - that BIOAIR developed over 20 years ago - in their standard configuration these cabinets are Class II type A and can be converted into Type B3, by ducting outside the laboratory. In Type A configuration a secondary exhaust HEPA can be retrofitted, in order to allow recirculation in the laboratory, as prescribed by BS5726.
Operating mode: in Type A configuration, the air leaving the Main HEPA filter at a constant speed produces a laminar downflow Class 100 environment. An air barrier enters through the front opening and is mixed with the downflown air underneath the work surface. 70 % of the air is recirculated, 30 % is exhausted through the exhaust HEPA. In type B configuration the operating principle is the same, but the unit is ducted to the outside of the laboratory and the front barrier speed is increased to 0.5 m/sec.
Monitoring and Control system: AURA B Biosafety Class II cabinets are equipped with a new electronic control system. A soft-touch keyboard and a bar-graph monitor both the barrier and downflow air speed ensuring the safest operating conditions at all times.
An elapsed-time meter audible and visible alarms allow the user to control filter life and immediately detect any problem linked with air flow.
In compliance with BS5726 1992, DIN12950 Teil 10, IEC 66.5 Œ Dual skin configuration (negative pressure contaminated air plenums surrounding the work chamber) for the highest safety. Perforated removable work surface and inner chamber in grade SS 304. Grade 3 stainless steel sump for the easiest cleanability 2-fans configuration. |
|
> Electrical equipment according to international Standards and EMC Directives
> Standard configuration: soft touch control panel, electrical power outlet, vacuum tap, solenoid gas valve, elapsed time meter, fluorescent lights, safety glass, front closure panel (equipped for UV option)
> Soft touch keys on the control panel provide control of the lighting, UV lamp (if fitted), electrical power outlet and solenoid valve
> The air velocity bargraph indicators give continuous monitoring of the air flow conditions
> Visible and acoustic alarms are activated when the laminar and exhaust flow rates fall or exceed the fixed thresholds and when the front window is not dosed securely
> Three sizes to satisfy all applications
> Exhaust Activated carbon filter option
> Centrifugal motor-blowers
> Electrical equipment according to International Standards and EMC directives
> Lighting > 1000 lux -
> Noise level < 58 dB (A)
> Cabinet outer surfaces made of cold rolled steel with paint finish
> Inner chamber made of grade 3 stainless steel with radiused corners and full access to exposed surfaces for ease of cleaning
> Removable work surface (split into three parts for easy steam sterilisation in autoclave) made of grade 3 stainless steel with perforated work area
> Unique sump made of grade 3 stainless steel with coved corners for easy removal of spilled liquids
> Stainless steel plenum
> HEPA filter manufactured in accordance with MIL-F51068 and BS-3928, with an efficiency higher than 99.999% on 0.3 µ particles, DOP tested. |
|
|
AURA B3 |
AURA B4 |
AURA B6
|
Work Chamber Dimensions
(lxpxh)
|
885x580x652 mm |
1190x580x652 mm |
1800x580x652 mm |
Overall Dimensions (lxpxh)
|
1135x797x1375 mm |
1440x797x1375 mm |
1375x797x1375 mm |
Weight
|
170 Kg |
225 Kg |
345 Kg |
Power Supply
|
230V - 50Hz |
230V - 50Hz |
230V - 50Hz |
Power Requirement
|
1,9 k W |
1,9kW |
2,2kW |
Noise Level
|
< 58 dB(A) |
< 58 dB(A) |
< 58 dB(A) |
Lighting
|
> 1000 lux |
> 1000 lux |
> 1000 lux |
Vibrations
|
< 0,006 mm-rms |
< 0,006 mm-rms |
< 0,006 mm-rms |
|
|
BSC-EN Cabinets
Microprocessor Controlled With Single
or Double Fan
Foreword
BSC-EN safety cabinets belong to the latest generation of laminar airflow systems, combining rigid safety requirements with high quality construction.
BSC-EN has been designed as a Class II Biohazard cabinet according to EN-12469.
Therefore it provides vertical laminar airflow with part of the air recirculated via the main HEPA filter whilst the remaining part is discharged through an exhaust HEPA filter. This cabinet is suitable for handling CDC 1-3, DPAG C-B1-B2 etiologic agents, providing operator, product and environmental protection
Applications
BSC-EN cabinets can be used in a wide range of disciplines, as defined in appropriate standards.
Especially suitable for applications such as:
- Microbiology
- Virology
- Haematology
- Cell culture
- Recombinant DNA
Benefits
- Handling of hazardous agents to human beings or animals as defined in the appropriate international standards.
- Sophisticated microprocessor based monitoring system
- Sophisticated microprocessor based system of audible and visual alarms alerts the operator if the cabinet does not operate in complete safety.
- Self-adjusting system to ensure a constant laminar airflow speed even in the presence of a progressive clogging of the filters.
- The negative pressure plenum "bio-dynamic sealing" ensures that all contaminated particles are kept inside the system and are automatically drawn to the pressure chamber to be captured and by the main and exhaust filters.
- The fan system assures that no part of the cabinet is under positive contaminated pressure to the laboratory, thus preserving environment and personnel from bio-contamination risks.
- Access from the front panel for ease of maintenance service.
- Alarms for:
- display of power rating factor of the main and exhaust (if installed) motor-blowers.
- out of range laminar airflow velocity and front air barrier velocity
- front window opened.
- HEPA filters clogging
- UV lamp worn-out (if installed)
- charcoal filter (if installed) saturated
- blackout
- Power Supply : 230V, 50Hz, single phase.
- signal of other possible malfunctions and relevant remedies.
- two vacuum or gas connections in the working area are provided, one with manual tap, the other with solenoid valve (on the right-hand side).
- A stainless steel spillage tray beneath the work surface collects spilt liquids.
- A stainless steel front closure panel ensures the sealing of the cabinet for sterilization/fumigation .
- An inlet allows the DOP test of the absolute HEPA filters.
- Electrical socket with protection IP-44 (on the right-hand side)
-
- As Option:
- Maintenance: access to filters, motor-blower/s and control panel by lifting the front panel.
- UV lamp for sterilization of the work chamber installed onthe front closure, controlled by two timers, one with 0¸3 hours scale (1 minute steps), the other 3 fixed hours.
- Available in one motor (BSC-EN S) as well as two motors (BSC-EN D) versions for flexible performance selection in line with the cabinet's use.
- AISI-316 stainless steel perforated work surface in 3, 4, or 6 pieces
- AISI-316 stainless steel solid work surface in 1,3, 4, or 6 pieces
-
- Lighting: fluorescent tubes in built-in housing, placed outside the contaminated area.
- Front window : Stratified safety glass, to give ease of access for large items.
- It is provided with gas spring to keep it open during maintenance or sanitization operations.
-
Additional Features:
- two vacuum or gas connections in the working area are provided, one with manual tap, the other with solenoid valve (on the right-hand side).
- A stainless steel spillage tray beneath the work surface collects spilt liquids.
- A stainless steel front closure panel ensures the sealing of the cabinet for sterilization/fumigation .
- An inlet allows the DOP test of the absolute HEPA filters.
- Electrical socket with protection IP-44 (on the right-hand side)
- Maintenance: access to filters, motor-blower/s and control panel by lifting the front panel.
- As Option:
- UV lamp for sterilization of the work chamber installed onthe front closure, controlled by two timers, one with 0¸3 hours scale (1 minute steps), the other 3 fixed hours.
Data:
Code
|
Model
|
Useful dimensions mm
|
Overall dimensions mm
|
|
|
W
|
H
|
D
|
W
|
H
|
D
|
O74 600110
|
BSC-EN 1-3
|
885
|
660
|
580
|
1090
|
1470
|
780
|
O74 600120
|
BSC-EN 1-4
|
1190
|
660
|
580
|
1395
|
1470
|
780
|
O74 600130
|
BSC-EN 1-5
|
1495
|
660
|
580
|
1700
|
1470
|
780
|
O74 600140
|
BSC-EN 1-6
|
1800
|
660
|
580
|
2005
|
1470
|
780
|
O74 600210
|
BSC-EN 2-3
|
885
|
660
|
580
|
1090
|
1470
|
780
|
O74 600220
|
BSC-EN 2-4
|
1190
|
660
|
580
|
1395
|
1470
|
780
|
O74 600230
|
BSC-EN 1-5
|
1495
|
660
|
580
|
1700
|
1470
|
780
|
O74 600240
|
BSC-EN 2-6
|
1800
|
660
|
580
|
2005
|
1470
|
780
|
Working aperture mm
|
Exhaust duct Æ
|
Temperature rise
|
Volts
Hz
|
Noise
dBA
|
Lighting
lux
|
Vibration
mm rms
|
200
|
200mm
|
<4° C
|
230/50
|
<65
|
>750
|
<0.005
|
BH-EN 2000
Class II Microbiological Safety Cabinet (MSC)
Microprocessor controlled with single or double fan
FOREWORD
BH-EN 2000 Class II Microbiological Safety cabinets belong to the latest generation of laminar airflow systems, combining rigid safety requirements with high quality construction. BH-EN 2000 has been designed as a Class II Microbiological Safety cabinets according to EN-12469. Therefore it provides vertical laminar airflow with part of the air recirculated via the main HEPA filter whilst the remaining part is discharged through an exhaust HEPA filter. This cabinet is suitable for handling CDC 1-3, DPAG C-B1-B2 etiologic agents, providing operator, product and environmental protection
APPLICATIONS
BH-EN 2000 cabinets can be used in a wide range of disciplines, as defined in appropriate standards. Especially suitable for applications such as:
- Microbiology
- Virology
- Haematology
- Cell culture
- Recombinant DNA
- Handling of hazardous agents to human beings or animals as defined in the appropriate international standards.
BENEFITS
- Sophisticated microprocessor based monitoring system Sophisticated microprocessor based system of audible and visual alarms alerts the operator if the cabinet does not operate in complete safety.
- Self-adjusting system to ensure a constant laminar airflow speed even in the presence of a progressive clogging of the filters.
- The negative pressure plenum "bio-dynamic sealing" ensures that all contaminated particles are kept inside the system and are automatically drawn to the pressure chamber to be captured and by the main and exhaust filters.
- The fan system assures that no part of the cabinet is under positive contaminated pressure to the laboratory, thus preserving environment and personnel from bio-contamination risks.
- Access from the front panel for ease of maintenance service.
- Available in one motor (BH-EN 2000 S) as well as two motors (BH-EN 2000 D) versions for flexible performance selection in line with the cabinet's use.
SPECIFICATIONS
Construction: Epoxy powder painted steel for improved strength and resistance to corrosion and atmospheric agents.
Work Surface: 3, 4, 5 or 6 pieces (depending on the cabinet width) AISI-316L stainless steel, completely perforated to ensure flow laminarity and air recycling at the work surface level. Frontal slots in the access area provide air barrier protection preventing any exchange of air between the inside of the cabinet and the environment.
On request the following work surfaces are available with no extra charges:
- AISI-316L stainless steel perforated work surface in 1 piece
- AISI-316L stainless steel solid work surface in 1 piece or 3, 4, 5, 6 pieces (depending on the cabinet width).
Work Chamber: in AISI-304 stainless steel sheet.
Absolute Filter: HEPA filters, tested with D.O.P. aerosol. Their efficiency, higher than 99,995%MPPS - 0.005% penetration - ensures a performance exceeding the requirements ofEN 1822, U.S. Federal Standard 209 e, British Standard 5295, VDI-2083 and AS 1386-1976.
The filtration system is designed to provide a barrier of air with minimum average speed over 0.4m/sec. according to EN-12469.
Motor-blower/s: One centrifugal fan (BH-EN 2000 S) and two centrifugal fans (BH-EN 2000 D), direct driven motors, with protection factor IP-55, controlled by two automatic speed regulators and microprocessor system showing laminar flow and protection barrier work conditions.
Microprocessor based monitoring system: new generation system for controlling the cabinet in a full digital way performs high level control and data processing. The handy and practical keyboard and the rearlit LCD display keep the user constantly informed of the cabinet conditions and operation, in particular:
- display of laminar airflow velocity and frontal air barrier velocity
- display of inside and outside temperature
- display of residual lifetime of HEPA filters, U.V. Lamp and charcoal filter (if installed)
- display of total time of cabinet operation
- display of power rating factor of the main and exhaust (if installed) motor-blowers.
Alarms for:
- out of range laminar airflow velocity and front air barrier velocity
- front window opened.
- HEPA filters clogging
- UV lamp worn-out (if installed)
- charcoal filter (if installed) saturated
- blackout
- signal of other possible malfunctions and relevant remedies.
Power Supply: 230V, 50Hz, single phase.
Lighting: fluorescent tubes in built-in housing, placed outside the contaminated area.
Front window: Stratified safety glass, to give ease of access for large items. It is provided with gas spring to keep it open during maintenance or sanitization operations.
Additional Features:
- two vacuum or gas connections in the working area are provided, one with manual tap, the other with solenoid valve (on the right-hand side).
- A stainless steel spillage tray beneath the work surface collects spilt liquids.
- A stainless steel front closure panel ensures the sealing of the cabinet for sterilization/fumigation .
- An inlet allows the DOP test of the absolute HEPA filters.
- Electrical socket with protection IP-44 (on the right-hand side)
Maintenance: access to filters, motor-blower/s and control panel by lifting the front panel.
As Option:
- UV lamp for sterilization of the work chamber installed onthe front closure, controlled by two timers, one with 0¸3 hours scale (1 minute steps), the other 3 fixed hours. |
Code
|
Model
|
Useful
Dimensions mm
|
Overall
Dimensions mm
|
Power
|
Weight
|
|
|
W
|
H
|
D
|
W
|
H
|
D
|
Kw
|
Kg
|
F74 600100
|
BH-EN 2003-S
|
885
|
660
|
580
|
1090
|
1470
|
785
|
0.7
|
181
|
F74 600120
|
BH-EN 2004-S
|
1190
|
660
|
580
|
1395
|
1470
|
785
|
1
|
213
|
F74 600130
|
BH-EN 2005-S
|
1495
|
660
|
580
|
1700
|
1470
|
785
|
1.2
|
260
|
F74 600140
|
BH-EN 2006-S
|
1800
|
660
|
580
|
2005
|
1470
|
785
|
1.4
|
298
|
F74 600210
|
BH-EN 2003-D
|
885
|
660
|
580
|
1090
|
1470
|
785
|
0.85
|
186
|
F74 600220
|
BH-EN 2004-D
|
1190
|
660
|
580
|
1395
|
1470
|
785
|
1.1
|
218
|
F74 600230
|
BH-EN 2005-D
|
1495
|
660
|
580
|
1700
|
1470
|
785
|
1.3
|
265
|
F74 600240
|
BH-EN 2006-D
|
1800
|
660
|
580
|
2005
|
1470
|
785
|
1.5
|
304
|
FrontAperture
|
Temperature rise
|
Exhaust duct
|
Noise level
|
Lighting
|
Vibrations
|
200mm
|
< 4°C
|
Ø200 mm
|
<59 dBA
|
>1000 lux
|
<0.005 mm RMS
|
|
|
BHG 2000
Class II Microbiological Safety Cabinet
Microprocessor controlled with electrically operated sash window
FOREWORD
BHG Class II Microbiological Safety cabinets belong to the latest generation of laminar airflow systems, combining rigid safety requirements with high quality construction.
BHG has been designed as a Class II Microbiological Safety cabinets according to EN-12469.
Therefore it provides vertical laminar airflow with part of the air recirculated via the main HEPA filter whilst the remaining part is discharged through an exhaust HEPA filter. This cabinet is suitable for handling CDC 1-3, DPAG C-B1-B2 etiologic agents, providing operator, product and environmental protection
BHG cabinets are provided with electrically operated, vertically sliding safety glass sash window
APPLICATIONS
BHG cabinets can be used in a wide range of disciplines, as defined in appropriate standards.
Especially suitable for applications such as:
- Microbiology
- Virology
- Haematology
- Cell culture
- Recombinant DNA
- Handling of hazardous agents to human beings or animals as defined in the appropriate international standards.
BENEFITS
- Sophisticated microprocessor based monitoring system
- Sophisticated microprocessor based system of audible and visual alarms alerts the operator if the cabinet does not run in complete safety.
- Self-adjusting system to ensure a constant laminar airflow speed even in the presence of a progressive clogging of the filters.
- The negative pressure plenum "bio-dynamic sealing" ensures that all contaminated particles are kept inside the system and are automatically drawn to the pressure chamber to be captured by the main and exhaust filters.
- The fan system assures that no part of the cabinet is under positive contaminated pressure to the laboratory, thus preserving environment and personnel from bio-contamination risks.
- Access from the front panel for ease of maintenance service.
- Available in one motor (BHG 2004 S) as well as two motors (BHG 2004 D) versions for flexible performance selection in line with the cabinet's use.
- The electrically driven sash window (easily moved up and down by merely pressing the keys placed on the front panel) can be completely closed or opened to make the operator's work easier.
SPECIFICATIONS
Construction: Epoxy power painted steel for improved strength and resistance to corrosion and atmospheric agents.
Work Surface: 3, 4 or 6 pieces (depending on the cabinet width) AISI-316L stainless steel, completely perforated to ensure flow laminarity and air recycling at the work surface level. Frontal slots in the access area provide air barrier protection preventing any exchange of air between the inside of the cabinet and the environment.
On request the following work surfaces are available with no extra charges:
- AISI-316L stainless steel perforated work surface in 1 piece
- AISI-316L stainless steel solid work surface in 1 piece or 3, 4, 6 pieces (depending on the cabinet width).
Absolute Filters: HEPA filters, tested with D.O.P. aerosol. Their efficiency, higher than 99,995% MPPS - 0.005% penetration - ensures a performance exceeding the requirements of EN 1822, U.S. Federal Standard 209 e and AS 1386-1976.
The filtration system is designed to provide a barrier of air with minimum average speed over 0.4m/sec. according to EN-12469.
Motor-blower/s: One centrifugal fan (BHG 2004 S) and two centrifugal fans (BHG 2004 D), direct driven motors, with protection factor IP-55, controlled by two automatic speed regulators and microprocessor system showing laminar flow and protection barrier work conditions.
Microprocessor based monitoring system: new generation system for controlling the cabinet in a full digital way performs high level control and data processing.
The handy and practical keyboard and the rearlit LCD display keep the user constantly informed of the cabinet conditions and operation, in particular:
- display of laminar airflow velocity and frontal air barrier velocity
- display of inside and outside temperature
- display of residual lifetime of HEPA filters, U.V. Lamp and charcoal filter (if installed)
- display of total time of cabinet operation
- display of power rating factor of the main and exhaust (if installed) motor-blowers.
Alarms for:
- out of range laminar airflow velocity and front air barrier velocity
- front window out of the working position (200 mm).
- HEPA filters clogging
- UV lamp worn-out (if installed)
- charcoal filter (if installed) saturated
- blackout
- signal of other possible malfunctions and relevant remedies.
Power Supply: 230V, 50Hz, single phase.
Lighting: fluorescent tubes in built-in housing, placed outside the contaminated area.
Front window: Stratified safety glass. The 3 degrees sloping fronted window optimizes the visibility inside the work chamber. When the cabinet is off, the window can be opened to 465 mm maximum or can be completely closed.
Additional Features:
- two vacuum or gas connections in the working area are provided, one with manual tap, the other with solenoid valve (on the right-hand side).
- A stainless steel spillage tray beneath the work surface collects spilt liquids.
- An inlet allows the DOP test of the absolute HEPA filters.
- Electrical socket with protection IP-44 (on the right-hand side)
- Maintenance: access to filters, motor-blower/s and control panel by lifting the front panel.
As option
- UV lamp for sterilization of the work chamber installed on a stainless steel front closure, controlled by two timers, one with 0¸3 hours scale (1 minute steps), the other 3 fixed hours.
|
|
Code
|
Model
|
Useful
Dimensions mm
|
Overall
Dimensions mm
|
Power
|
Weight
|
|
|
W
|
H
|
D
|
W
|
H
|
D
|
Kw
|
Kg
|
F74 700110
|
BHG 2003-S
|
885
|
655
|
606
|
1090
|
1470
|
865
|
0.9
|
191
|
F74 700120
|
BHG 2004-S
|
1190
|
655
|
606
|
1395
|
1470
|
865
|
1.2
|
223
|
F74 700140
|
BHG 2006-S
|
1800
|
655
|
606
|
2005
|
1470
|
865
|
1.6
|
310
|
F74 700210
|
BHG 2003-D
|
885
|
655
|
606
|
1090
|
1470
|
865
|
1.0
|
196
|
F74 700220
|
BHG 2004-D
|
1190
|
655
|
606
|
1395
|
1470
|
865
|
1.3
|
228
|
F74 700240
|
BHG 2006-D
|
1800
|
655
|
606
|
2005
|
1470
|
865
|
1.7
|
314
|
FrontAperture
|
Temperature rise
|
Exhaust duct
|
Noise level
|
Lighting
|
Vibrations
|
200mm
|
< 4°C
|
Ø200 mm
|
<59 dBA
|
>1000 lux
|
<0.005 mm RMS
|
|
|
|
ULTRASAFE
Class II Microbiological Safety Cabinet (MSC)
Microprocessor controlled with single or double fan
FOREWORD
Faster UltraSafe Microbiological Safety Cabinets belong to the latest generation of laminar airflow systems manufactured by Faster, in which the choice of materials of construction of the highest quality guarantees conformity to the strictest safety standards. Faster UltraSafe vertical laminar flow cabinets are Class II Microbiological Safety Cabinets - designed and built to performance requirements of the EN-12469:2000 European Standard, with 70% of the air re-circulated via the main Class H14 HEPA filter within the cabinet, whilst the remaining 30% is discharged through an exhaust Class H14 HEPA filter.
APPLICATIONS
Faster UltraSafe Class II Microbiological Safety Cabinets have been adopted worldwide in use for product, personnel and environmental protection while handling harmful agents pathogenic to human beings and/or animals as defined in the appropriate international standards, in a wide range of disciplines in applications such as: Microbiology, Virology, Haematology, Cell culture, Genetics, Handling of hazardous agents to human beings or animals
BENEFITS
Ergonomic Design. The angled sloping front safety-glass sash provides optimum visibility of all objects placed in the interior workspace. The sash is electrically operated. Pressing the appropriate touch-sensitive keys will completely open or completely close down the sash.
The standard sash-height opening during work is set to 250 mm. Alternative sash-height settings by the factory are possible upon request. The whole front of the safety cabinet – which includes the sash mechanism – can also be opened upwards as it is hinged on the top – in order to allow easy access for complete and effective cleaning and decontamination.
Inflatable gasketing is also available as an option to provide effective sealing of the internal workspace of the chamber for purposes of fumigation/sterilization.
Silent Operation. The textile plenum, the structures of the electric motors of the fans fitted on their antivibration mounts and the software itself designed to provide optimum airhandling characteristics guarantee quiet operation of this silent safety cabinet, with sound-pressure levels recorded way below the parameters specified in the current EN:12469 European Standard for Microbiological Safety Cabinets.
Protection grid A protection grid made of AISI 304 stainless steel is provided inside the part behind the rear panel (where air flows), in order to avoid de-contamination costs would the tissue used during cleaning operations be sucked in the motor-blower causing the failure of the blower itself and/or of anemometer.
High Level Lighting. The safety glass side-windows with the ideal positoning and sizing of the light-system provide the highest level of luminosity to the work area.
Easy handling and maintenance. The safety cabinet can pass through 800 mm wide door openings. In fact, the overall depth of the cabinet can be reduced to approx. 790 mm by removal of the rear panel. All service operations are available from the front of the cabinet.
SPECIFICATIONS
Rear wall in stainless steel AISI 304L, designed to conform to requirements and pass the “cleanability test” according to EN12469:2000.
AISI 316 work surface consisting of sections which are easily removable for carrying out routine cleaning and/or autoclaving sterilization procedures; closed or perforated on request.
Re-circulating and extractor fans: FASTER UltraSafe Microbiological Safety Cabinets ‘S’-Series are supplied with single centrifugal fan, whilst models of the ‘D’ Series with double centrifugal fan to provide complete operator, product and environmental protection. Moreover the ‘D’ models fitted with double motor-fan are designed and are also suitable to discharge the filtered air outside the laboratory through a ducting system if required.
Microprocessor based monitoring system: full status report provided via digital display by the new generation microprocessors – which automatically control all functions and all safety alarm systems ensuring that performance characteristics are maintained to EN12469:2000 requirements. High power lithium battery keeps safety data saved to microprocessor system
The user-friendly practical keyboard and the rear-lit LCD will continuously display all required data keeping the user constantly informed of the cabinet conditions in operation, and in particular:
- display of laminar airflow velocity and frontal air barrier velocity
- display of inside and outside temperature
- display of residual lifetime of HEPA filters, UV Lamp and activated carbon filter (if fitted)
- display of total number of hours of operation
- display of saturation level of HEPA filters.
Audio-visual alarms provided for:
- Out of range or incorrect laminar airflow velocity and frontal air barrier velocity
- Uncorrect position of front sash-window
- saturation of HEPA filters
- end of life-cycle of UV lamp and saturation of activated carbon filter (if fitted)
- blockage in the exhaust duct
- fan-motor malfunction
- power failure
UV sterilizing lamp (optional) complete two switch-off countdown timers, one variable on a 0¸3 hours scale (1 minute steps), the other set to 3 fixed hours.
OPTIONAL
- UV Lamp with full programable timer
- Customized work surfaces
- Epoxy powder painted modular stand
- Stainless Steel modular stand
- Electrical adjustable stand (700-1000 mm height)
- Additional electrical power socket
- Additional service connection for gas/vacuum (manual tap)
- Additional socket for data (RS232, RS485 or RJ45)
- Additional exhaust Carbon filter for UltraSafe (only D model)
- Additional exhaust HEPA filter for UltraSafe (only D model)
- Anti-blowback valve
- Exhaust hard duct connection
- Exhaust thimble connection
- 3-Drawers unit on pivotting wheels
- Volt free contact
- Arm rest
- Inflatable Gasket for front sealing
- Vacuum pump for inflatable gasket
- Sealing kit for exhaust opening
- Formalin Vaporizer with ammonia neutralization
DIMENSIONAL TABLE
|
Code
|
Model
|
Useful
Dimensions mm
|
Overall
Dimensions mm
|
Power
|
Weight
|
|
|
W
|
H
|
D
|
W
|
H
|
D
|
Kw
|
Kg
|
F74800110
|
ULTRASAFE
209 S
|
899
|
700
|
600
|
1045
|
1500
|
860
|
0.7
|
170
|
F74800120
|
ULTRASAFE
212 S
|
1194
|
700
|
600
|
1350
|
1500
|
860
|
1
|
195
|
F74800130
|
ULTRASAFE
215 S
|
1499
|
700
|
600
|
1655
|
1500
|
860
|
1.2
|
225
|
F74800140
|
ULTRASAFE
218 S
|
1804
|
700
|
600
|
1960
|
1500
|
860
|
1.4
|
260
|
F74800210
|
ULTRASAFE
209 D
|
899
|
700
|
600
|
1045
|
1500
|
860
|
0.85
|
175
|
F74800220
|
ULTRASAFE
212 D
|
1194
|
700
|
600
|
1350
|
1500
|
860
|
1.1
|
200
|
F74800230
|
ULTRASAFE
215 D
|
1499
|
700
|
600
|
1655
|
1500
|
860
|
1.3
|
230
|
F74800240
|
ULTRASAFE
218 D
|
1804
|
700
|
600
|
1960
|
1500
|
860
|
1.5
|
265
|
FrontAperture
|
Temperature rise
|
Noise level
|
Lighting
|
Vibrations
|
250mm
|
< 3 °C
|
<57 dBA
|
>1000 lux
|
<0.004 mm RMS
|
|
Class II Cabinets - Faster
|
SafeFAST Elite Microbiological Safety Cabinets belong to the latest generation of laminar airflow systems manufactured by Faster, in which the choice of materials of construction of the highest quality guarantees conformity to the strictest safety standards. Faster SafeFAST Elite vertical laminar flow cabinets are Class II Microbiological Safety Cabinets - designed and built to performance requirements of the EN-12469:2000 European Standard, with 70% of the air re-circulated via the main Class H14 HEPA filter within the cabinet, whilst the remaining 30% is discharged through an exhaust Class H14 HEPA filter.
APPLICATIONS
SafeFAST Elite Class II Microbiological Safety Cabinets have been adopted worldwide in use for product, personnel and environmental protection while handling harmful agents pathogenic to human beings and/or animals as defined in the appropriate international standards, in a wide range of disciplines in applications such as: Microbiology, Virology, Haematology, Cell culture, Genetics, Handling of hazardous agents to human beings or animals
BENEFITS
Ergonomic Design. The angled sloping front stratified safety-glass sash provides optimum visibility of all objects placed in the interior workspace. The sash is electrically operated. Pressing the appropriate touch-sensitive keys will completely open or completely close down the sash. The standard sash-height opening during work is set to 200 mm. Alternative sash-height settings by the factory are possible upon request. The whole front of the safety cabinet – which includes the sash mechanism – can also be opened upwards as it is hinged on the top – in order to allow easy access for complete and effective cleaning and decontamination.
ECS® Eco Controling System: The new ECS® microprocessor employs the latest innovative methods of integrated management of all principal functions of ventilation and filtration - self-regulating all the main filtration and ventilation system components - compensating for declining pressure drops and restoring power balance. Combining the use of AC motor-blowers and certified low pressure-drop filters, the new ECS® controlling system optimize power consumption, reducing CO2 emissions into the environment
Anti Bacterial Coating: Exclusive Dupont™ ALESTA® anti-bacterial “Ag+ cations-based solution”, capable to prevent microbial contamination of surfaces thereby inhibiting long term surface growth
Inflatable gasketing is also available as an option to provide effective sealing of the internal workspace of the chamber for purposes of fumigation/sterilization and when gas-tight is needed
Silent Operation. The TNT plenum, the structures of the electric motors of the fans fitted on their antivibration mounts and the software itself designed to provide optimum air handling characteristics guarantee quiet operation of this silent safety cabinet, with sound-pressure levels recorded way below the parameters specified in the current EN:12469 European Standard for Microbiological Safety Cabinets.
Protection grid. A protection grid made of AISI 304L stainless steel is provided inside the part behind the rear panel (where air flows), in order to avoid the tissue used during cleaning operations be sucked in the motor-blower causing the failure of the blower and other damages
High Level Lighting. The safety glass side-windows with the ideal positioning and sizing of the light-system provide the highest level of luminosity to the work area.
Easy handling and maintenance. The safety cabinet can pass through standard 800 mm wide door openings. In fact, the overall depth of the cabinet can be reduced to approx. 790 mm by removal of the rear panel. All service operations are available from the front of the cabinet.
SPECIFICATIONS
Rear wall in stainless steel AISI 304 L, designed to conform to requirements and pass the “cleanability test” according to EN12469:2000.
AISI 316L work surface consisting of sections which are easily removable for carrying out routine cleaning and/or autoclaving sterilization procedures; closed or perforated on request.
Re-circulating and extractor fans: FASTER SafeFAST Elite Microbiological Safety Cabinets ‘S’-Series are supplied with single centrifugal fan, whilst models of the ‘D’ Series with double centrifugal fan ( main and exhaust ) to provide complete operator, product and environmental protection. Moreover the ‘D’ models fitted with double motor-fan are designed and are also suitable to discharge the filtered air outside the laboratory through a ducting system if required.
Operation Condition: Class ISO 3 as per ISO:EN 14644-1
The user-friendly practical keyboard and the rear-lit LCD will continuously display all required data keeping the user constantly informed of the cabinet conditions in operation, and in particular:
• display of laminar airflow velocity and frontal air barrier velocity
• display of inside and outside temperature
•display of residual lifetime of HEPA filters, UV Lamp and activated carbon filter (if fitted)
• display of total number of hours of operation
• display of saturation level of HEPA filters.
Audio-visual alarms provided for:
• out of range or incorrect laminar airflow velocity and frontal air barrier velocity
• uncorrect position of front sash-window
• clogging of HEPA filters
• end of life-cycle of UV lamp and saturation of activated carbon filter (if fitted)
• blockage in the exhaust duct ( if fitted )
• fan-motor malfunction
• power failure
UV sterilizing lamp (optional) complete two switch-off countdown timers, one variable on a 0-3 hours scale (1 minute steps), the other set to 3 fixed hours.
OPTIONAL
• Magnetic UV Lamp with full programmable timer
• Customized work surfaces
• Epoxy powder painted modular stand
• Stainless Steel modular stand
• Electrical adjustable stand (700-1000 mm height)
• Additional electrical power socket
• Additional service connection for gas/vacuum (manual tap)
• Additional socket for data (RS232, RS485 or RJ45)
• Additional exhaust Carbon filter (only D model)
• Additional exhaust HEPA filter (only D model)
• Anti-blowback valve
• Exhaust hard duct connection
• Exhaust thimble connection
• 3-Drawers unit on pivotting wheels
• V olt free contact
• Arm rest
• Inflatable Gasket for front sealing
• Vacuum pump for inflatable gasket
• Sealing kit for exhaust opening
• Formalin Vaporizer with ammonia neutralization
Technical Information
Model: |
Elite 209 D |
Elite 212 D |
Elite 215 D |
Elite 218 D |
Power: |
0.85 |
1.1 |
1.3 |
1.5 |
Front Closure: |
Sliding Sash |
Sliding Sash |
Sliding Sash |
Sliding Sash |
Front Aperture: |
200mm |
200mm |
200mm |
200mm |
Lighting: |
>1000 lux |
>1000 lux |
>1000 lux |
>1000 lux |
Fan: |
Double |
Double |
Double |
Double |
Noise Level: |
<55 dBA |
<55 dBA |
<55 dBA |
<55 dBA |
Vibrations: |
<0.004 mm RMS |
<0.004 mm RMS |
<0.004 mm RMS |
<0.004 mm RMS |
Overall Dimensions (WxHxD): |
1045 x 1500 x 860 |
1350 x 1500 x 860 |
1655 x 1500 x 860 |
1960 x 1500 x 860 |
Useful Dimensions (WxHxD): |
887 x 740 x 580 |
1192 x 740 x 580 |
1497 x 740 x 580 |
1802 x 740 x 580 |
|
Class II Cabinets - Faster
|
SafeFAST Top Microbiological Safety Cabinets belong to the latest generation of laminar airflow systems manufactured by Faster, in which the choice of materials of construction of the highest quality guarantees conformity to the strictest safety standards. Faster UltraSafe vertical laminar flow cabinets are Class II Microbiological Safety Cabinets - designed and built to performance requirements of the EN-12469:2000 European Standard, with 70% of the air re-circulated via the main Class H14 HEPA filter within the cabinet, whilst the remaining 30% is discharged through an exhaust Class H14 HEPA filter.
APPLICATIONS
SafeFAST Top Class II Microbiological Safety Cabinets have been adopted worldwide in use for product, personnel and environmental protection while handling harmful agents pathogenic to human beings and/or animals as defined in the appropriate international standards, in a wide range of disciplines in applications such as: Microbiology, Virology, Haematology, Cell culture, Genetics, Handling of hazardous agents to human beings or animals.
BENEFITS
ECS® Eco Controling System: The new ECS® microprocessor employs the latest innovative methods of integrated management of all principal functions of ventilation and filtration – self regulating all the main filtration and ventilation system components - compensating for declining pressure drops and restoring power balance. Combining the use of AC motor-blowers and certified low pressure-drop filters, the new ECS® controlling system optimize power consumption, reducing CO2 emissions into the environment.
Anti Bacterial Coating: exclusive Dupont™ ALESTA® anti-bacterial “Ag+ cations-based solution”, capable to prevent microbial contamination of surfaces thereby inhibiting long term surface growth
• Self-adjusting system to ensure a constant laminar airflow speed even in the presence of a progressive clogging of the filters.
• The negative pressure plenum " bio-dynamic sealing " ensures that all contaminated particles are kept inside the system and are automatically drawn to the pressure chamber to be captured and by the main and exhaust filters.
•The fan system assures that no part of the cabinet is under positive contaminated pressure to the laboratory, thus preserving environment and personnel from bio-contamination risks.
• Access from the front panel for ease of maintenance service.
• Available in one motor ( S Version ) as well as two motors( D Version ) versions for flexible performance selection in line with the cabinet's use.
SPECIFICATIONS
Construction: Epoxy powder painted steel for improved strength and resistance to corrosion and atmospheric agents.
Work Surface: 3, 4, 5 or 6 pieces (depending on the cabinet width) AISI-316L stainless steel, completely perforated to ensure flow laminarity and air recycling at the work surface level. Frontal slots in the access area provide air barrier protection preventing any exchange of air between the inside of the cabinet and the environment.
Alternative on request the following work surfaces are available with no extra charges:
• AISI-316L stainless steel perforated work surface in 1 piece
• AISI-316L stainless steel solid work surface in 1 piece or 3, 4, 5, 6 pieces (depending on the cabinet width).
Work Chamber : in AISI-304 L stainless steel sheet.
Absolute Filter : Class H14 HEPA filters. Efficiency, higher than 99,995% MPPS - 0.005% penetration - ensures a performance exceeding the requirements of EN 1822,
Operation Condition : Class ISO 3 as per ISO:EN 14644-1
Motor-blower/s: One centrifugal fan ( SafeFAST top S ) and two centrifugal fans ( SafeFAST elite D ), direct driven motors, with protection factor IP-55, controlled by two automatic speed regulators and microprocessor system showing laminar flow and protection barrier work conditions.
Front window: Stratified safety glass, to give ease of access for large items. It is provided with gas spring to keep it open during maintenance or sanitization operations.
The user-friendly practical keyboard and the rearlit LCD display will continuosly display all required data keeping the user cobstantly informed of the cabinet conditions in operation, and in particular:
• display of laminar airflow velocity and frontal air barrier velocity
• display of inside and outside temperature
• display of residual lifetime of HEPA filters, U.V. Lamp and activated carbon filter ( if installed )
• display of total time of cabinet operation
• display of saturation level of Hepa filter
Alarms for:
• Out of range or incorrect laminar airflow velocity and front air barrier velocity
• Front window opened
• HEPA filters clogging
• End of UV cycle
• Saturation of Activated carbon filter (if installed)
• Power failure
• Signal of other possible malfunctions and relevant remedies
• Blockage in the exhaust duct ( if ducted )
• Power Supply: 230V, 50Hz, single phase.
• Lighting: fluorescent tubes in built-in housing, placed outside the contaminated area.
Additional Features:
• Two vacuum or gas connections in the working area are provided, one with manual tap, the other with solenoid valve (on the right-hand side).
• A stainless steel spillage tray beneath the work surface collects spilt liquids.
• A stainless steel front closure panel ensures the sealing of the cabinet for sterilization/fumigation .
• An inlet allows the DOP-DEHS test of the absolute HEPA filters.
• Electrical socket with protection IP-44 (on the right-hand side)
• Maintenance: access to filters, motor-blower/s and control panel by lifting the front panel.
OPTIONAL
• UV Lamp, installed on tha aluminium night door complete on two switch-off countdown timers, one variable on a 0-3 hours scale (1 minute steps), the other set to 3 fixed hours.
• Customized work surfaces
• Epoxy powder painted modular stand w or w/o castors
• Stainless Steel modular stand
• Electrical adjustable stand (700-1000 mm height)
• Additional electrical power socket
• Additional service connection for gas/vacuum (manual tap)
• Additional socket for data (RS232, RS485 or RJ45)
• Additional exhaust Carbon filter (only D model)
• Additional exhaust HEPA filter (only D model)
• Anti-blowback valve
• Exhaust thimble connection
• 3-Drawers unit on pivotting wheels
• Volt free contact
• Arm rest
• Sealing kit for exhaust opening
• Formalin Vaporizer with ammonia neutralization
• Damper
• Pre-filter grid
• Floor stand 900mm working height with footrest
• Electrical adjustable floor stand (800 to 1100mm working height)
Technical Information
Model: |
Top 209 D |
Top 212 D |
Top 215 D |
Top 218 D |
Power: |
0.85 |
1.1 |
1.3 |
1.5 |
Front Closure: |
Night Door |
Night Door |
Night Door |
Night Door |
Front Aperture: |
200mm |
200mm |
200mm |
200mm |
Lighting: |
>1000 lux |
>1000 lux |
>1000 lux |
>1000 lux |
Fan: |
Double |
Double |
Double |
Double |
Noise Level: |
<58 dBA |
<58 dBA |
<58 dBA |
<58 dBA |
Vibrations: |
<0.004mm RMS |
<0.004mm RMS |
<0.004mm RMS |
<0.004mm RMS |
Overall Dimensions (WxHxD): |
1015 x 1470 x 785 |
1320 x 1470 x 785 |
1625 x 1470 x 785 |
1930 x 1470 x 785 |
Useful Dimensions (WxHxD): |
885 x 660 x 580 |
1190 x 660 x 580 |
1495 x 660 x 580 |
1800 x 660 x 580 |
|
Class II Cabinets - Faster
|
SafeFAST Classic Microbiological Safety Cabinets belong to the latest generation of laminar airflow systems manufactured by Faster, in which the choice of materials of construction of the highest quality guarantees conformity to the strictest safety standards. Faster SafeFAST Classic vertical laminar flow cabinets are Class II Microbiological Safety Cabinets - designed and built to performance requirements of the EN-12469:2000 European Standard, with 70% of the air re-circulated via the main H14 HEPA filter according to EN 1822 within the cabinet, whilst the remaining 30% is discharged through an exhaust H14 HEPA filter.
APPLICATIONS
SafeFAST Classic Class II Microbiological Safety Cabinets have been adopted worldwide for product, personnel and environmental protection while handling harmful agents pathogenic to human beings and/or animals as defined in the appropriate international standards, in a wide range of applications such as: Microbiology, Virology, Haematology, Cell culture, Genetics, Handling of hazardous agents to human beings or animals -
BENEFITS
Ergonomic Design: The angled sloping front glass sash provides optimum visibility of all objects placed in the interior workspace. The sash is electrically operated. Pressing the appropriate touch-sensitive keys will completely open or completely close down the sash. The standard sash-height opening during work is set to 200 mm. Alternative sash-height settings are available upon request.
ECS® Eco Controling System: The new ECS® microprocessor employs the latest innovative methods of integrated management of all principal functions of ventilation and filtration - self-regulating all the main filtration and ventilation system components - compensating for increasing pressure drops and restoring power balance. Combining the use of AC motor-blowers and certified low pressure-drop filters, the new ECS® controlling system optimize power consumption, reducing CO2 emissions into the environment
Anti Bacterial Coating: Exclusive Dupont™ ALESTA® anti-bacterial “Ag+ cations-based solution”, capable to prevent microbial contamination of surfaces thereby inhibiting long term surface growth
Silent Operation: The TNT plenum, the structure of the electric motor of the fan fitted on their anti-vibration mounts and the software itself designed to provide optimum air handling characteristics, guarantee quiet operation of this silent safety cabinet, with sound-pressure levels recorded way below the parameters specified in the current EN:12469:2000 European Standard for Microbiological Safety Cabinets.
High Level Lighting: The glass side windows with the ideal positioning and sizing of the light-system provide the highest level of luminosity to the work area
Easy handling and maintenance: The safety cabinet can pass through standard 800 mm wide door openings. In fact, the overall depth of the cabinet can be reduced to 790 mm by removal of the rear panel. All service operations are available from the front of the cabinet.
SPECIFICATIONS
Rear wall in epoxy coated steel, designed to conform to requirements and pass the “cleanability test” according to EN12469:2000
AISI 304L, work surface consisting of sections which are easily removable for carrying out routine cleaning and/or autoclaving sterilization procedures; plain or perforated on request
Re-circulating and extractor fan, FASTER SafeFAST Classic Microbiological Safety Cabinets Series are supplied with single centrifugal fan
Servicing side glass with ports for gas/vacuum taps installation
Operation Condition: Class ISO 3 as per ISO:EN 14644-1
Electrical outlet IP44 rated
The user-friendly practical keyboard and the rear-lit LCD will continuously display all required data keeping the user constantly informed of the cabinet conditions in operation, and in particular:
• display of laminar airflow velocity and frontal air barrier velocity
• display of residual lifetime of HEPA filters, UV Lamp and activated carbon filter (if fitted)
• display of total number of hours of operation
• display of saturation level of HEPA filters
• display of fan power ( 0-100% )
Audio-visual alarms provided for:
• out of range or incorrect laminar airflow velocity and frontal air barrier velocity
• uncorrect position of front sash-window
• clogging of HEPA filters
• end of life-cycle of UV lamp and saturation of activated carbon filter ( if fitted )
• blockage in the exhaust duct ( if fitted )
• fan-motor malfunction
• power failure
UV sterilizing lamp (optional) complete with two timers, one timer fully programmable by the operator with starting and duration time, one countdown variable on a 0-3 hours scale (1 minute steps)
OPTIONAL
• Solid work surface
• Single section work surface
• Magnetic UV lamp with full programmable timer
• Additional tap ( Fuel Gas/Non Fuel Gas/Vacuum )
• Additional electrical outlet
• Stainless steel hanging bar
• Movable stainless steel Arm rest
• Exhaust thimble connection
• Pre-filter grid
• Electrical adjustable height stand ( 700 to 1000mm height )
• Stand with castors
Technical Information
Model: |
Classic 209 |
Classic 212 |
Classic 218 |
Power: |
0.7 |
1.0 |
1.4 |
Front Closure: |
Sliding Sash |
Sliding Sash |
Sliding Sash |
Front Aperture: |
200mm |
200mm |
200mm |
Lighting: |
>1200 lux |
>1200 lux |
>1200 lux |
Fan: |
Single |
Single |
Single |
Noise Level: |
<54 dBA |
<54 dBA |
<54 dBA |
Vibrations: |
<0.004mm RMS |
<0.004mm RMS |
<0.004mm RMS |
Overall Dimensions (WxHxD): |
1045 x 1500 x 810 |
1350 x 1500 x 810 |
1960 x 1500 x 810 |
Useful Dimensions (WxHxD): |
887 x 740 x 580 |
1192 x 740 x 580 |
1802 x 740 x 580 |
|
S@feflow 1.2
MICROBIOLOGICAL SAFETY CABINET CLASS II
|
|
|
S@feflow 1.2 is a microbiological safety cabinet (MSC) CLASS II, Type A, B3 convertible designed to provide protection to the operator, the product and the environment, against risks due to airborne contamination.
S@afeflow 1.2 is built according with the latest European standards CE 12469-2000
|
MAIN SPECIFICATIONS
|
|
Ventilation of the cabinet includes recirculating air flow filtered through high efficency filter (HEPA) and a make up air, passing to the front opening and then discharged through an exaust HEPA filter into the environment.
Recirculated and make up air flows are mantained at a pre-set value by a close-loop microprocessor, which automatically monitors and controls the air volumes, assisted by an avanced volumetric sensor.
S@feflow MSC has a sloped front ergonomically designed to maximise the operating confort and user friendlyness of the construction.
An electrically operated sliding sash can be moved up and down at different opening heights: at a finger tip touch, an electronic device automatically searches for the optimised height of the front opening. Moreover the sash is hinged at the topallowing easy cleaning of the internal surface of the glass.
The microprocessor has a large, high resolution display, and all functions available for both operator and service staff are easily operated trough multi task switches.
|
|
|
Main functions included:
> Display of speed/volume values of air (downflow and front barrier)
> Alarms (three levels of alarms plus secondary alarms)
> Introduction of two different passwords to enter operational or engineer modes
> Automatic fumigation cycle (with automatic set-up of front sliding sash at defined heights in the different phases of fumigation cycle)
> UV cycles control
> Filter life
> UV lamps life
|
|
|
S@feflow 1.2 |
Work Chamber Dimensions
(lxpxh)
|
1180 x 570 x 680 mm |
Overall Dimensions (lxpxh)
|
1360 x 790 x 1505 mm |
Weight
|
270 Kg |
Power Supply
|
230 volt - 50 hz |
Power Requirements |
2,2 kW |
|
|
Cytotoxic Cabinets - Faster
|
The CytoFAST Elite cabinet has been designed to protect both the material to be manipulated from contamination and to protect the operator and the environment from cytotoxic contamination and harmful agents.
CytoFAST Elite has been manufactured according to EN 12469:2000 and DIN 12980:2005 standards, with about 70% laminar flow re-circulated air and 30% exhausted air with prior HEPA filtering.
Third bank of class H14 HEPA filters with easy replace system is positioned beneath work surface Built for handling cytotoxic drugs CytoFAST Elite is also suitable for product, personnel and environment protection while handling harmful agents pathogenic to human beings and/or animals as defined in the appropriate international standards.
APPLICATIONS
CytoFAST Elite cabinet is especially suitable for applications such as: preparation and handling of cytotoxic drugs, preparations of CMR drugs, presence of agents likely to cause genetic alterations or synergetic activities with other materials.
Since CytoFAST Elite cabinets meet also EN12469:2000 as for Class II Microbiological Safety Cabinets, they can be used also for: Microbiology, Virology, Haematology, Cell culture, Recombinant DNA.
BENEFITS
Ergonomic Design. The angled sloping front stratified safety-glass sash provides optimum visibility of all objects placed in the interior workspace. The sash is electrically operated. Pressing the appropriate touch-sensitive keys will completely open or completely close down the sash. The standard sash-height opening during work is set to 200 mm. Alternative sash-height settings by the factory are possible upon request. The whole front of the safety cabinet – which includes the sash mechanism – can also be opened upwards as it is hinged on the top – in order to allow easy access for complete and effective cleaning and decontamination.
ECS® Eco Controling System: The new ECS® microprocessor employs the latest innovative methods of integrated management of all principal functions of ventilation and filtration - self-regulating all the main filtration and ventilation system components - compensating for declining pressure drops and restoring power balance. Combining the use of AC motor-blowers and certified low pressure-drop filters, the new ECS® controlling system optimize power consumption, reducing CO2 emissions into the environment
Anti Bacterial Coating: Exclusive Dupont™ ALESTA® anti-bacterial “Ag+ cations-based solution”, capable to prevent microbial contamination of surfaces thereby inhibiting long term surface growth
Inflatable gasketing is also available as an option to provide effective sealing of the internal workspace of the chamber for purposes of fumigation/sterilization and when gas-tight is needed
Silent Operation. The TNT plenum, the structures of the electric motors of the fans fitted on their anti-vibration mounts and the software itself designed to provide optimum air handling characteristics guarantee quiet operation of this silent safety cabinet, with sound-pressure levels recorded way below the parameters specified in the current EN:12469 European Standard for Microbiological Safety Cabinets.
Protection grid. A protection grid made of AISI 304L stainless steel is provided inside the part behind the rear panel (where air flows), in order to avoid the tissue used during cleaning operations be sucked in the motor-blower causing the failure of the blower and other damages
High Level Lighting. The safety glass side-windows with the ideal positioning and sizing of the light-system provide the highest level of luminosity to the work area.
Easy handling and maintenance. The safety cabinet can pass through standard 800 mm wide door openings. In fact, the overall depth of the cabinet can be reduced to approx. 790 mm by removal of the rear panel. All service operations are available from the front of the cabinet.
CytoFAST Elite has a demountable base stand of 255 mm. Without this stand the cabinet height is 1995 mm and can easily pass through doors of 2 meters height.
SPECIFICATIONS
Rear wall in stainless steel AISI 304 L, designed to conform to requirements and pass the “cleanability test” according to EN12469:2000 and DIN 12980:2005.
AISI 316L work surface consisting of sections which are easily removable for carrying out routine cleaning and/or autoclaving sterilization procedures; closed or perforated on request.
Re-circulating and extractor fans: FASTER CytoFAST Elite is supplied with double centrifugal fan ( main and exhaust ) to provide complete operator, product and environmental protection. Moreover are designed and are also suitable to discharge the filtered air outside the laboratory through a ducting system if required.
Operation Condition: Class ISO 3 as per ISO:EN 14644-1
The user-friendly practical keyboard and the rear-lit LCD will continuously display all required data keeping the user constantly informed of the cabinet conditions in operation, and in particular:
• Display of laminar airflow velocity and frontal air barrier velocity
• Display of inside and outside temperature
• Display of residual lifetime of HEPA filters, UV Lamp and activated carbon filter (if fitted)
• Display of total number of hours of operation
• Display of saturation level of HEPA filters.
Audio-visual alarms provided for:
• Out of range or incorrect laminar airflow velocity and frontal air barrier velocity
• Uncorrect position of front sash-window
• Clogging of HEPA filters
• End of life-cycle of UV lamp and saturation of activated carbon filter (if fitted)
• Blockage in the exhaust duct ( if fitted )
• Fan-motor malfunction
• Power failure
UV sterilizing lamp (optional) complete two switch-off countdown timers, one variable on a 0-3 hours scale (1 minute steps), the other set to 3 fixed hours.
OPTIONS
Magnetic U.V. Lamp with full programmable timer .
SPECIAL USES
For special uses a version with activated charcoal filter instead of the multidihedral HEPA filters, located under the work surface, is available.
Technical Information
Model: |
Elite 209 |
Elite 212 |
Elite 218 |
Overall Dimensions mm
WxHxD(1)(4) |
1045x2345x855 |
1350x2345x855 |
1960x2345x855 |
Usefull Dimensions mm
WxHxD |
887x740x580 |
1192x740x580 |
1802x740x580 |
Working aperture mm |
200* |
Maximum front aperture mm |
440 |
Weight kg |
215 |
245 |
325 |
Exhaust flow rate m3/h |
290 |
390 |
585 |
Noise level (2) dB(A) |
<53 |
<54 |
<56 |
Lighting level lux |
>1100 |
>1200 |
>1300 |
Electrical Data |
1Ph+E - 230V 50Hz |
Current consumption (2)(3) A |
2,3 |
3,0 |
4,5 |
Electrical class / IP |
1 / 20 |
Internal electrical outlet |
The electrical outlets have a total load capacity of 4A |
Heat emission W |
175 |
240 |
360 |
(1)The total depth of the cabinet can be easily reduced to 790 mm removing the back panel.
(2) At operation condition according to EN12469: 2000 and DIN 12980:2005.
(3) Clean filters, lighting activated, internal outlet load excluded.
(4) The total height of the cabinet excluding a removable stand for moving through the door is 1995 mm.
* Alternative sash-height settings (250-160 mm) by the factory are available upon request |
|
|
HORIZONTAL LAMINAR AIR FLOW CABINET CLASS 100 |
|
|
HORIZONTAL LAMINAR AIR FLOW SELF CALIBRATING CABINET CLASS 100 FOR PRODUCT PROTECTION.
HZ cabinets are designed according to the most advanced electronic and aerodynamic Technologies in order to ensure a Contamination Controlled Environment of the highest Quality.
Main applications for AURA HZ are:
> Media preparation
> Plant and animal tissue culture
> Pharmaceutical preparations
> Assembling of optical or mic-electronic components
> Micro-mechanics
|
MAIN SPECIFICATIONS
|
|
Microprocessor control: AURA HZ is a horizontal laminar air flow cabinet, Class 100, for product protection from external contamination and cross-contamination inside the working chamber. The air speed is, for the highest product safety, permanently controlled via a microprocessor unit linked to an integral vane anemometer installed in the unit as a standard option.
Venturi-effect side walls: special tempered-glass side walls are installed inside the air flow, to prevent any leakage from the outside. Operating mode: the air flow, leaving the HEPA filter at a constant speed, produces an extremely clean - better than Class 100 - environment in the work area, preventing any contamination to enter from the ambient outside. High efficiency washable polyurethane prefilters remove coarse particles in advance of the air reaching the HEPA filter.
Cabinet outer surfaces made of cold-rolled steel, with paint finish. Stainless steel work surface. HEPA filter with 99,999% efficiency on 0,3 µ particles DOP tested Side walls in safety tempered glass.
|
|
> Microprocessor controlled air speed
> Centrifugal motor-blower
> Bar graph display for air speed value
> Soft touch keys on the control panel provide control of the lighting, elapsed time meter, motorblower, UV light, solenoid valve and power point.
> Visible and acoustic alarms are provided for air speed alarm and filter dogging
> Three sizes to satisfy all applications.
> Electrical equipment according to International Standards and EMC directives
> Lighting > 1000 lux
> Noise level < 58 dB (A)
> Cabinet outer surfaces made of cold rolled steel with paint finish
> Working surface made of grade 3 stainless steel
> Side panels in tempered glass
> HEPA filter manufactured in accordance with MIL-F51068 and BS-3928, with an efficiency higher than 99.999% on 0,3 µ particles, DOP tested.
> Micromesh membrane on HEPA filter downstream surface for perfect air speed distribution.
> Œ marked
|
|
|
AURA HZ 36 |
AURA HZ 48 |
AURA HZ 72 |
Work Chamber Dimensions
(lxpxh)
|
815x610x732 mm |
1120x610x732 mm |
1730x610x732 mm |
Overall Dimensions (lxpxh)
|
1045x1063x1353 mm |
1350x1063x1353 mm |
1960x1063x1353 mm |
Weight
|
105 Kg |
128 Kg |
194 Kg |
Power Supply
|
230V - 50Hz |
230V - 50Hz |
230V - 50Hz |
Power Requirements
|
0,4 k W |
0,42 k W |
0,8 k W |
Noise Level
|
< 59 dB |
< 59 dB |
< 59 dB |
Lighting
|
> 1000 lux |
> 1000 lux |
> 1000 lux |
|
|
Faster Flow Cabinets BIO Vertical
|
BIO cabinets provide ISO Class 3 vertical laminar-flow. Most of the air is re-circulated through the HEPA filter, with part being expelled into the environment through the exhaust outlet. BI0 cabinets operate under negative pressure after sterilisation through the HEPA filter and provide Class 100 air according to Federal Standard 209e. They therefore protect the product from micro-organisms and air borne contaminants. The balanced, perforated work surface and design of the working aperture provide an excellent flow laminarity at the work level.
APPLICATIONS
These cabinets have been specifically designed to meet the demands of modern industrial laboratories, primarily for handling cell cultures and no-hazardous biological agents, when it is necessary to ensure product protection.
BIO cabinets have applications in a wide range of disciplines, including:
•Quality control of pharmaceuticals and food industries
•Microbiology
•Cell culture
•Sterile handling
SPECIFICATIONS
Construction for mod. BIO 48/60/72: AISI-304L stainless steel to provide hygienic conditions.
Construction for mod. BIO 48M/60-M/72-M: corrosion resistant epoxy powder painted steel.
Work surface: glazed AISI-stainless steel completely perforated to ensure flow laminarity and air recycling at the work surface level.
Transparent side walls: safety glass.
Absolute filter: HEPA filter, tested with D. O. P. aerosol. Their efficiency, higher than 99.999% at 0.3 micron particle size -0.001%penetration -ensures performance exceeding requirements of U. S. Federal Standard 209 e, British Standard 5295, VDI-2083 and AS 1386-1976.
Motor blower: direct coupled motor, electronic speed controlled to maintain a constant air flow of 0.45 m/sec, and compensate for a partially clogged filter up to a maximum plenum pressure of 40 mm of water.
Power Supply: 220 V, 50 Hz, single phase. Other voltages available on request.
Lighting: remote mounted fluorescent light, outside sterile area.
Front window: safety glass window with camlock.
Spillage tray: a painted spillage tray for mod. BIO-M or AISI-304L stainless steel spillage tray for mod. BI0 beneath the work surface collects spilt liquid.
Additional Features: the work area is equipped with a manual gas tap and IP-44 electrical socket.
Technical Information
Model: |
48-M |
60-M |
72-M |
Overall Dimensions mm
WxHxD |
1312x1430x765 |
1617x1430x765 |
1922x1430x765 |
Usefull Dimensions mm
WxHxD |
1220x640x580 |
1525x640x580 |
1830x640x580 |
Front aperture mm |
170 |
Temperature rise |
< 3 °C |
Noise level dB(A) |
<55 dBA |
Lighting |
>1000 lux |
Vibrations |
<0.004 mm RMS |
Exhausted Air |
150 |
160 |
300 |
Power Kw |
0.6 |
0.7 |
0.8 |
|
Laminar Flow Cabinets - Vertical - Faster
|
FlowFAST V cabinets provide ISO Class 3 vertical laminar-flow. The external air of the laboratory pass through the prefilter on the top of the cabinet and then through the through the HEPA H14 filter, with most of the part being exhausted from the front and small percentage being recirculated trough the two series of slots on the back wall. FlowFAST V cabinets operate in positive pressure after sterilisation through the HEPA filter and provide Class 100 air according to Federal Standard 209e. They therefore protect the product from micro-organisms and air borne contaminants. The two series slot on the back panel
and design of the working aperture provide an excellent flow laminarity at the work level.
APPLICATIONS
These cabinets have been specifically designed to meet the demands of modern industrial laboratories, primarily for handling cell cultures and no-hazardous biological agents, when it is necessary to ensure product protection.
FlowFAST V cabinets have applications in a wide range of disciplines, including:
· Quality control of pharmaceuticals and food industries
· Microbiology
· Cell culture
· Sterile handling
Technical Information
Model: |
12 |
15 |
18 |
Usefull Dimensions mm
WxHxD |
1190x710x625 |
1495x710x625 |
1800x710x625 |
Construction for mod. FFV 12/15/18: |
corrosion resistant epoxy powder painted
steel coated with Alesta Dupont antimicrobial coating |
Work surface: |
one piece AISI 304-stainless steel |
Transparent side walls: |
safety glass |
Absolute filter: |
HEPA filter, tested with D. O. P. aerosol. Their efficiency, higher
than 99.999% at 0.3 micron particle size -0.001%penetration -ensures
performance exceeding requirements of U. S. Federal Standard 209 e, British Standard 5295, VDI-2083 and AS 1386-1976 |
Motor blower: |
direct coupled motor, electronic speed controlled to maintain a
constant air flow of 0.45 m/sec, and compensate for a partially clogged filter up to a maximum plenum pressure of 40 mm of water |
Power Supply: |
220 V, 50 Hz, single phase. Other voltages available on request |
Lighting: |
remote mounted fluorescent light, outside sterile area |
Front window: |
slopped safety glass window for better ergonomy with hinges
maintaining the front window opened by itself |
Additional Features: |
the work area as standard with one IP-44 electrical socket.
Gas and vacuum taps available as additional accessories |
|
Laminar Flow Cabinets - Horizontal - Faster
|
FlowFAST H Cabinets are ISO Class 3 horizontal laminar flow cabinets which represent far more economical and valid alternatives to clean-rooms, as they are capable of providing uncontaminated, particle-free and sterile conditions for materials in the work-space. They guarantee and maintain excellent product protection factors by offering a decontaminated working area by virtue of the pre-filter with a minimum efficiency of 80%-90% ASHRAE - and the HEPA filter with an efficiency better than 99,995 % MPPS ( H14 - EN:1822 ). The FlowFast H horizontal laminar airflow cabinets have epoxy powder coated steel structures and an AISI 304L stainless steel working surface as standard. Laminated working surface available on demand. Alternatively special models made in AISI 304L stainless steel for superior cleanability are also available on demand.
APPLICATIONS
FlowFAST H have been adopted in use for product protection from airborne contamination or while handling not pathogenic biological specimens in applications such as:
• Sterility Test,
• Microbiology,
• In Vitro Fertilization,
• Preparation of ophthalmic solutions,
• Preparation of culture media,
• Assembly of electronic devices,
•Nutritional Parenteral Therapy,
•Assembly of medical devices.
SPECIFICATIONS
Construction: Corrosion resistant epoxy powder painted steel ( as standard )
Anti Bacterial Coating: exclusive Dupont™ ALESTA® anti-bacterial “Ag+ cations-based solution”, capable to prevent microbial contamination of surfaces thereby inhibiting long term surface growth
Work Surface: AISI-304L stainless steel (as standard) or non reflective plastic laminate (on demand)
Transparent side walls: safety glass
Absolute filter: Class H14 HEPA filter. Efficiency, higher than 99.995% MPPS -0.005%penetration -ensures performance exceeding requirements of EN1822
Operation Conditions: Class ISO 3 as per ISO:EN 14644-1
Pre-filters: G3 synthetic fibres pre-filters washable in water or with compressed air
ECS® Eco Controlling System: The new ECS® microprocessor employs the latest innovative methods of integrated management of all principal functions of ventilation and filtration – self regulating all the main filtration and ventilation system components - compensating for declining pressure drops and restoring power balance. Combining the use of AC motor-blowers and certified low pressure-drop filters, the new ECS® controlling system optimize power consumption, reducing CO2 emissions into the environment
Motor-blower : direct coupled motorblower,
Lighting: fluorescent lights installed on the anterior part of the ceiling
OPTIONALS
• Epoxy powder painted stand
• Shutter
• Shutter fitted with UV light
• Automatic speed regulator and digital anemometer
• D.O.P. inlet
• Service connection for electrical power
• Service connection for gas/vacuum ( manual tap )
• Differential pressure gauge
• Hour counter
• Stainless steel bar for bags
Technical Information
Model: |
FlowFAST 09 |
FlowFAST 12 |
FlowFAST 15 |
FlowFAST 18 |
Overall Dimensions mm
WxHxD |
945x1195x925 |
1250x1195x925 |
1555x1195x925 |
1860x1195x925 |
Usefull Dimensions mm
WxHxD |
884x734x600 |
1190x734x600 |
1494x734x600 |
1800x734x600 |
Working aperture mm |
735 |
Weight kg |
104 |
122 |
171 |
194 |
Noise level dB(A) |
<60 |
Electrical Supply |
230V 50Hz |
Power Kw |
0,70 |
0,90 |
1,40 |
1,40 |
|
KBN
Horizontal Laminar Flow Cabinet
The KBN horizontal laminar air flow benches are the most advanced alternative to sterile rooms, providing highly decontaminated working areas.
Sterile horizontal benches for product contamination protection are constructed either in AISI 304 stainless steel or in epoxy powder painted steel. The wide choice of sizes and materials enables many different applications; each version is supplied with either stainless steel or nonreflective plastic laminate work surfaces.
APPLICATIONS
KBN horizontal laminar airflow benches can be used in a wide range of disciplines, including:
- Sterile manipulation
- Sterility tests
- Microbiology
- Preparation of ophthalmic solutions
- Preparation of culture media
- Assembly of equipment
- Floriculture
- TPN preparation
- Medical device assembly
SPECIFICATIONS
Construction: Corrosion resistant epoxy powder painted steel (as standard); glazed AISI 304 stainless steel (on demand)
Work Surface: AISI-304 stainless steel (as standard) or non reflective plastic laminate (on demand)
Transparent side walls: safety glass
Absolute filter: HEPA filter, tested with D. 0. P aerosol. Their efficiency, higher than 99.995% MPPS -0.005%penetration -ensures performance exceeding requirements of EN1822, U. S. Federal Standard 209 e, British Standard 5295, VDI-2083 and AS 1386-1979.
Pre-filters: synthetic fibers pre-filters washable in water or with compressed air, average arrestance 80/90%ASHRAE (CEN-G3); dust holding capacity 400 g/m2.
Motor-blower (s): direct coupled motor (s), electronic speed controlled to maintain a constant air flow of 0.45 m/sec, and compensate for a partially clogged filter, up to a maximum plenum pressure of 40 mm of water.
Power supply: 230 V -50 Hz, single phase. Other voltages on request.
Lighting: fluorescent lights installed on the anterior part of the ceiling. |
|
Code
|
Model
|
Useful
Dimensions mm
|
Overall
Dimensions mm
|
Power
|
Weight
|
|
|
W
|
H
|
D
|
W
|
H
|
D
|
Kw
|
Kg
|
F74 200210 |
KBN3
|
885
|
734
|
600
|
945
|
1195
|
925
|
0.4
|
100
|
F74 200220 |
KBN4
|
1190
|
734
|
600
|
1250
|
1195
|
925
|
0.4
|
125
|
F74 200230 |
KBN5
|
1495
|
734
|
600
|
1555
|
1195
|
925
|
0.8
|
180
|
F74 200240 |
KBN6
|
1800
|
734
|
600
|
1860
|
1195
|
925
|
0.8
|
195
|
|
|
MINILAB
Vertical Laminar Flow Cabinet
FOREWORD
is a compact, economical new concept in vertical laminar airflow workstations. MINILAB uses very little bench space, yet provides a decontaminated bench top work space in which to carry out manipulations which must be kept clean. MINILAB is easy to move and can also be placed in different laboratories.
APPLICATIONS
MINILAB can be used in a wide range of disciplines including:
- Microbiology
- Sterile manipulations
- Cell culture
SPECIFICATIONS
Construction: corrosion resistant epoxy powder painted steel.
Work surface: glazed AISI-304 perforated stainless steel -Removable for autoclaving
Transparent side walls and front windows: plexiglass.
Back side: opaque plexiglass.
Absolute filter: HEPA filter, tested with D. 0. P. aerosol. Their efficiency, higher then 99.999% at 0.3 micron particle size - 0.001% penetration - guarantees performance exceeding requirements of U. S. Federal Standard 209 e, BS 5295, VDI-2083 and AS 1386 -1976.
Prefilter: syntethic-fibers pre-filter (washable in water or with compressed air), average arrestance 80/90% ASHRAE (CEN-G3) dust holding capacity 400 g/m2.
Motor blower: direct coupled motor, electronic speed controlled to maintain a constant air flow of 0.45 m/sec, and compensate for a partially clogged filter up to a maximum plenum pressure of 35 mm of water.
Power Supply: 220 V, 50 Hz, single phase. Other voltages available on request. |
|
Code
|
Model
|
Useful
Dimensions mm
|
Overall
Dimensions mm
|
Power
|
Volts
|
Weight
|
Flow
Rate
|
|
|
W
|
H
|
D
|
W
|
H
|
H
|
Kw
|
Hz
|
Kg
|
m3/h
|
F72 799900 |
MINILAB |
580
|
375
|
317
|
642
|
830
|
340
|
0.11
|
220/50 |
50
|
290
|
|
|
Laminar Flow Cabinets - Vertical - Faster
|
SmartFAST laboratory cabinet ensures high containment reliability, providing a class ISO 3 working area highly protected from both air-born contaminants and no-hazordous micro-organisms .
Compact, economic and easy-to-place new concept of laminar flow cabinet, gives two working possibilities:
1.Overpressure system: part of the sterile air is exhausted through the front opening.
2.Depression system: part of the filtered air is exhausted, while air from outside is partially brought in through the front opening thus obtaining a protective barrier.
To exchange the two operational systems, it is sufficient to change the position of the closing plate on the top of the cabinet.
OPERATING PRINCIPLES
Configuration 1: OVERPRESSURE
The air stream flowing down in laminar air flow pattern from the HEPA filter passes through the perforated work surface. An air intake from the top side creates a slight positive pressure in the cabinet, which causes some of the air to be exhausted from the front aperture.
Configuration 2: DEPRESSION
The ambient air is drawn in through the slots of the stainless steel base at the front opening and it then passes under the work surface, from where it is drawn up and channeled after filtration through a HEPA filter in laminar air flow condition ( about 90% ) and exhausted outside ( about 10% ) from the upper side of the cabinet.
APPLICATIONS
SmartFAST has been specifically designed to meet specific requirements of biotechnology laboratories, molecular biology, electronics, pharmaceuticals and optical, primarily when handling cell cultures and no-hazardous biological agents, when it is necessary to ensure material protection.
Can be used in a wide range of disciplines, including:
• Microbiology
• Sterility tests
• Cell culture
• Sterile manipulations
• Molecular biology
• DNA work/thermal cycling/PCR
SPECIFICATIONS
Construction : corrosion-resistant epoxy powder painted carbon steel.
Transparent side walls: safety glass.
Work surface: Punched AISI-304L stainless steel, to ensure flow laminarity and air recycling at the work surface level. An air slot at the front aperture provides a protective barrier for product.
Absolute filter: HEPA filter tested with D. O. P. aerosol. Their efficiency, higher than 99.999% at 0.3 micron particle size -0.001% penetration (H14) -guarantees performance exceeding requirements of U. S. Federal Standard 209 e, BS 5295, VDI-2083 and AS 1386-1976.
Motor blower: direct coupled motor, electronic speed controlled to maintain a constant air flow of 0.45 m/sec, and compensate for a partially clogged filter, up to a maximum pressure of 35 mm of water.
Power Supply: 220 V, 50 Hz, single phase.
Lighting: remote mounted fluorescent light, outside sterile area.
Front window: safety glass with camlock.
Technical Information
Model: |
SmartFast |
Overall Dimensions (WxDxH) mm |
830x652x925 |
Useful Dimensions (WxDxH) mm |
732x380x580 |
Light Lux |
600 |
Noise Level dB (A) |
53 |
Code number |
F00012100000 |
Power Kw |
0.20 |
Supply V/Hz |
220-230/50 |
Weight kg |
75 |
|
Faster TWO 30 Vertical Laminar Flow Cabinet
FOREWORD
The TWO 30 laboratory cabinet ensures high containment reliability, providing a working area highly protected from both micro-organisms and air-born contaminants.
Compact, economic and easy-to-place new concept of laminar flow cabinet, gives two working possibilities:
1 Overpressure system
Part of the sterile air is exhausted through the front opening.
2 Depression system
Part of the filtered air is exhausted, while air from outside is partially brought in through the front opening thus obtaining a protective barrier.
To exchange the two operational systems, it is sufficient to change the position of the closing plate with the pre-filter and vice versa.
OPERATING PRINCIPLES
1 configuration: OVERPRESSURE
The air stream flowing down from the HEPA filter passes through the perforated work surface. An air intake from the side slot creates a slight positive pressure in the cabinet, which causes some of the air to exhaust from the front aperture.
2 configuration: DEPRESSION
The air flowing down from the HEPA filter passes through the perforated work surface. Air exhausted through a pre-filter placed on the upper surface of the cabinet provides a slight negative pressure in the cabinet, which causes a protective air barrier to develop at the working aperture, without affecting flow laminarity.
APPLICATIONS
TWO 30 has been specifically designed to meet specific requirements of electronics, pharmaceuticals, optical and biotechnology laboratories, primarily when handling cell cultures and no-hazardous biological agents, when it is necessary to ensure material protection.
Can be used in a wide range of disciplines, including:
- Microbiology
- Sterility tests
- Cell culture
- Sterile manipulations
- DNA work/thermal cycling/PCR
SPECIFICATIONS
Construction: corrosion-resistant epoxy powder painted carbon steel
Transparent side walls: safety glass
Work surface: Punched AISI-304 stainless steel, to ensure flow laminarity and air recycling at the work surface level. An air slot at the front aperture provides a protective barrier for product
Absolute filter: HEPA filter tested with D. O. P. aerosol. Their efficiency, higher than 99.999% at 0.3 micron particle size -0.001%penetration -guarantees performance exceeding requirements of U. S. Federal Standard 209 e, BS 5295, VDI-2083 and AS 1386-1976
Pre filter: synthetic fibre pre-filters (washable in water or with compressed air), average arrestance 80/90% ASHRAE (CEN-G3): dust holding capacity 400 g/m2
Motor blower: direct coupled motor, electronic speed controlled to maintain a constant air flow of 0.45 m/sec, and compensate for a partially clogged filter, up to a maximum pressure of 35 mm of water
Power Supply: 220 V, 50 Hz, single phase
Lighting: remote mounted fluorescent light, outside sterile area. The TWO 30 can be upgraded to a PCR cabinet by ordering the F72700300 UV lamp
Front window: safety glass with cam lock
Code
|
Model
|
Useful
Dimension mm
|
Overall
Dimension mm
|
Power
|
Weight
|
|
|
W
|
H
|
D
|
W
|
H
|
D
|
Kw
|
Kg
|
F72700320 |
TWO 30 |
790
|
585
|
400
|
845
|
785
|
660
|
0.2
|
75
|
Recycled Air
m3/H
|
Exhausted Air
m3/H
|
Temperature rise
|
Volts
Hz
|
Noise
dBA
|
Lighting
Lux
|
Vibrations
mm RMS
|
230
|
100
|
< 4°C
|
220/50
|
<60
|
>500
|
<0.008
|
LAMINAR DOWN-FLOW CABINET CLASS 100 |
Specifications
|
AURA MINI |
Work Chamber Dimensions (lxpxh)
|
737x428x510 mm |
Overall Dimensions (lxpxh)
|
(820+75)x580x1432 cm |
Weight
|
57 Kg |
Power Supply
|
230V - 50Hz |
Power Requirements
|
0,25 k W |
Noise Level
|
< 59 dB(A) |
Lighting
|
> 1000 lux |
Vibrations
|
< 0,006 mm - rms |
|
LAMINAR DOWN-FLOW CABINET CLASS 100 |
Specifications
|
AURA SD4 |
Work Chamber Dimensions
(lxpxh)
|
1240 x 485 x 650 mm |
Overall Dimensions (lxpxh)
|
1355 x 785 x 1457 mm |
Weight
|
175Kg |
Power Supply
|
230V - 50Hz |
Power Requirements
|
1.7Kw |
Lighting
|
>1000 lux |
Noise Level |
<58dB(A) |
Vibrations
|
<0.006mm rm |
|
LAMINAR DOWN-FLOW CABINET CLASS 100 |
Specifications
|
AURA VF 48 |
AURA VF 72 |
Work Chamber Dimensions
(lxpxh)
|
1190x580x675 mm |
1800x580x675 mm |
Overall Dimensions (lxpxh)
|
1350x850x1415 mm |
1960x850x1415 mm |
Weight
|
170 Kg |
230 Kg |
Power Supply
|
220V - 50Hz |
220V - 50Hz |
Power Requirement
|
1,7 k W |
1,95 k W |
Noise Level
|
< 59 dB(A) |
< 59 dB(A) |
Lighting
|
> 1000 lux |
> 1000 lux |
Vibrations
|
< 0,006 mm - rms |
< 0,006 mm - rms |
LS90 Cabinet
Foreword
The LS 90 laboratory cabinet ensures high containment reliability, providing a Class 100 working area highly protected from both micro-organisms and air-born contaminants.
Compact, economic and easy-to-place new concept of laminar flow cabinet, gives two working possibilities:
1 -Overpressure system
Part of the sterile air is exhausted through the front opening.
2 -Depression system
Part of the filtered air is exhausted, while air from outside is partially brought in through the front opening thus obtaining a protective barrier.
To exchange the two operational systems, it is sufficient to change the position of the closing plate with the pre-filter and viceversa.
Applications
LS 90 has been specifically designed to meet specific requirements of electronics, pharmaceuticals, optical and biotechnology laboratories, primarily when handling cell cultures and no-hazardous biological agents, when it is necessary to ensure material protection. Can be used in a wide range of disciplines, including:
Specifications
Construction: corrosion-resistant epoxy powder painted carbon steel.
Transparent side walls: safety glass.
Work surface: Punched AISI-304 stainless steel, to ensure flow laminarity and air recycling at the work surface level. An air slot at the front aperture provides a protective barrier for product.
Absolute filter: HEPA filter, tested with D.0.P. aerosol. Its efficiency, higher than 99.995% MPPS -0.005%penetration -ensures performance exceeding requirements of EN1822, U. S. Federal Standard 209 e, British Standard 5295, VDI-2083 and AS 1386-1979.
Pre-filters: synthetic fibers pre-filters (washable in water or with compressed air), average arrestance 80/90% ASHRAE (CEN-G3): dust holding capacity 400 g/m2.
Motor-blower: direct coupled motor, electronic speed controlled to maintain a constant air flow of 0.45 m/sec, and compensate for a partially clogged filter, up to a maximum pressure of 35 mm of water.
Power supply: 230 V, 50 Hz, single phase.
Lighting: remote mounted fluorescent light, outside sterile area.
Front window: safety glass with camlock.
Code
|
Model
|
Useful Dimensions mm
|
Overall Dimensions mm
|
Power
|
Weight
|
|
|
W
|
H
|
D
|
W
|
H
|
D
|
Kw
|
Kg.
|
O74 500220
|
LS-90
|
790
|
585
|
400
|
845
|
785
|
660
|
0.2
|
75
|
Recirculated Air
m3/h
|
Exhausted Air
m3/h
|
Temperature Rise
|
Volts
Hz
|
Noise
dBA
|
Lighting
lux
|
Vibrations
mm RMS
|
230
|
100
|
<4 ° C
|
230/50
|
<60
|
>500
|
<0.008
|
Accessories
Code
|
Desciptions
|
O74 704000
|
Epoxy powder modular stand for LS-90
|
O74 700300
|
UV lamp for LS-90 with stainless steel front closure
|
O74 700780
|
Hour counter
|
O74700740
|
Digital anemometer
|
O74 700750
|
Digital anemometer with automatic regulation
|
O74 700790
|
Differential pressure gauge
|
O74 709076
|
D.O.P. inlet
|
O74 700770
|
Electrical power socket
|
O74 700760
|
Manual tap for gas/vacuum
|
Faster Minilab Cabinet
Foreword
The Faster MINILAB is a compact, economical new concept in vertical laminar airflow workstations. MINILAB uses very little bench space, yet provides a decontaminated bench top work space in which to carry out manipulations which must be kept clean. MINILAB is easy to move and can also be placed in different laboratories.
Applications
MINILAB can be used in a wide range of disciplines including:
- Microbiology
- Sterile manipulations
Specifications
Construction: corrosion resistant epoxy powder painted steel.
Work surface: glazed AISI-304 perforated stainless steel -Removable for autoclaving
Transparent side walls and front window: plexiglass.
Back side: opaque plexiglass.
Absolute filter: HEPA filter, tested with D. 0. P. aerosol. Their efficiency, higher then 99.999% at 0.3 micron particle size - 0.001% penetration - guarantees performance exceeding requirements of U. S. Federal Standard 209 e, BS 5295, VDI-2083 and AS 1386 -1976.
Prefilter: syntethic-fibers pre-filter (washable in water or with compressed air), average arrestance 80/90% ASHRAE (CEN-G3) dust holding capacity 400 g/m2.
Motor blower: direct coupled motor, electronic speed controlled to maintain a constant air flow of 0.45 m/sec, and compensate for a partially clogged filter up to a maximum plenum pressure of 35 mm of water.
Power Supply : 220 V, 50 Hz, single phase.
Code
|
Model
|
Useful dimensions (mm)
|
Overall dimensions (mm)
|
Power
|
Volts
|
Weight
|
Flow Rate
|
W
|
H
|
D
|
W
|
H
|
D
|
Kw
|
Hz
|
Kg
|
m3/h
|
F72 799900
|
MINILAB
|
580
|
375
|
317
|
642
|
830
|
340
|
0.11
|
220/50
|
50
|
290
|
AURA PCR WORKSTATION. Passive PCR Cabinet
|
|
|
Passive PCR cabinet with UV lights for neutralisation of DNA in aerosols.
Specially designed for pre-amplification sample preparation in controlled environment. It prevents contamination due to PCR fragments previously amplified. |
With easy to clean PVC surface, 3 UV lamps,florescent lamp interlocked and UV timer. Internal adjustable tempered glass shelf.
|
|
|
MAIN SPECIFICATIONS |
|
Front opened, UV cabinet for the safe performing of all operations relevant to polymerase chain reactions for DNA production in the safest conditions for your work.
Any aerosol generated during the handling of the material is contained within the cupboard and any molecule of DNA herein contained is subsequently neutralised with the help of UV radiations.
Operating mode: PCR is a very easy to operate cabinet. When the normal working procedures have been completed, the tempered glass front panel is closed and a timer is activated in order to expose all internal surfaces and tools to UV radiation for a preset period of time.
The outer tempered glass body of the PCR cabinet, acting as a filter to UV radiations is safely protecting the external environment from dangerous exposure of personnel to those radiations.
The PCR cabinet complies with machine directives 89/392EC, which include the electromagnetic compatibility "EMC" according to 89/336EC.
The cabinet also complies with safety requirements for electrical equipment for laboratory use as per EN 61010-1. |
|
|
> Electrical equipment according to International Standards and EMC directives Standard configuration:
> Main structure: 6mm tempered glass,
> Service hinged tray: cold rolled steel with stove enamel coated RAL 7035 (grey).
> Top cover: cold rolled steel with stove enamel coated RAL 7035 (grey).
> Front window: 6mm tempered glass,
> Work surface: pvc
|
|
|
AURA PCR |
Overall Dimensions (lxpxh)
|
650 x 545x 730 mm |
Weight
|
25 Kg |
Power Supply
|
220/240V - 50Hz |
Power Requirements
|
100 W |
Lightning
|
>60 lux |
Standard option |
Fluorescent light switch
Timer for UV lights
Safety microswitch |
|
|
|
Faster Two-30
Foreword
The TWO 30 laboratory cabinet ensures high containment reliability, providing a working area highly protected from both micro-organisms and air-born contaminants.
Compact, economic and easy-to-place new concept of laminar flow cabinet, gives two working possibilities:
1 Overpressure system
Part of the sterile air is exhausted through the front opening.
2 Depression system
Part of the filtered air is exhausted, while air from outside is partially brought in through the front opening thus obtaining a protective barrier.
To exchange the two operational systems, it is sufficient to change the position of the closing plate with the pre-filter and viceversa.
Operating Principles
1. Configuration: Overpressure
The air stream flowing down from the HEPA filter passes through the perforated worksurface. An air intake from the side slot creates a slight positive pressure in the cabinet, which causes some of the air to exhaust from the front aperture.
2. Configuration: Depression
The air flowing down from the HEPA filter passes through the perforated worksurface. Air exhausted through a pre-filter placed on the upper surface of the cabinet provides a slight negative pressure in the cabinet, which causes a protective air barrier to develop at the working aperture, without affecting flow laminarity.
Applications
TWO 30 has been specifically designed to meet specific requirements of electronics, pharmaceuticals, optical and biotechnology laboratories, primarily when handling cell cultures and no-hazardous biological agents, when it is necessary to ensure material protection.
Can be used in a wide range of disciplines, including:
Specifications
Construction : corrosion-resistant epoxy powder painted carbon steel.
Transparent side walls: safety glass.
Work surface: Punched AISI-304 stainless steel, to ensure flow laminarity and air recycling at the work surface level. An air slot at the front aperture provides a protective barrier for product.
Absolute filter: HEPA filter tested with D. O. P. aerosol. Their efficiency, higher than 99.999% at 0.3 micron particle size -0.001%penetration -guarantees performance exceeding requirements of U. S. Federal Standard 209 e, BS 5295, VDI-2083 and AS 1386-1976.
Prefilter: synthetic fibers pre-filters (washable in water or with compressed air), average arrestance 80/90% ASHRAE (CEN-G3): dust holding capacity 400 g/m2.
Motor blower: direct coupled motor, electronic speed controlled to maintain a constant air flow of 0.45 m/sec, and compensate for a partially clogged filter, up to a maximum pressure of 35 mm of water.
Power Supply: 220 V, 50 Hz, single phase.
Lighting: remote mounted fluorescent light, outside sterile area.
Front window: safety glass with camlock.
Code
|
Model
|
Useful
Dimension (mm)
|
Overall
Dimension (mm)
|
Power
(Kw)
|
Weight
(Kg)
|
W
|
H
|
D
|
W
|
H
|
D
|
F72700320 |
TWO 30 |
790
|
585
|
400
|
845
|
785
|
660
|
0.2
|
75
|
Recycled Air
m3/H
|
Exhausted Air
m3/H
|
Temperature rise
|
Volts
Hz
|
Noise
dBA
|
Lighting
Lux
|
Vibrations
mm RMS
|
230
|
100
|
< 4°C
|
220/50
|
<60
|
>500
|
<0.008
|
VS Cabinet
FOREWARD
VS cabinets provide vertical laminar-flow. Most of the air is recirculated through the HEPA filter, with part being expelled into the environment through the exhaust outlet. VS cabinets operate under negative pressure after sterilisation through the HEPA filter and provide Class 100 air according to Federal Standard 209e. They therefore protect the product from micro-organisms and air borne contaminants. The balanced, perforated work surface and design of the working aperture provide an excellent flow laminarity at the work level.
APPLICATIONS
These cabinets have been specifically designed to meet the demands of modern industrial laboratories, primarily for handling cell cultures and no-hazardous biological agents, when it is necessary to ensure product protection.
VS cabinet have applications in a wide range of disciplines, including:
SPECIFICATIONS
Construction: corrosion resistant epoxy powder painted steel.
Work surface: glazed AISI-stainless steel completely perforated to ensure flow laminarity and air recycling at the work surface level.
Transparent side walls: safety glass.
Absolute filter: HEPA filter, tested with
D. 0. P aerosol. Its efficiency, higher than 99.995% MPPS -0.005% penetration -ensures performance exceeding requirements of EN1822, U. S. Federal Standard 209 e, British Standard 5295, VDI-2083 and AS 1386-1979.
Motor-blower: direct coupled motor, electronic speed controlled to maintain a constant air flow of 0.45 m/sec, and compensate for a partially clogged filter up to a maximum plenum pressure of 40 mm of water.
Power supply: 230 V, 50 Hz, single phase. Other voltages available on request.
Lighting: remote mounted fluorescent light, outside sterile area.
Front window: safety glass window with camlock.
Spillage tray: a painted spillage tray beneath the work surface collects spilt liquid.
Additional features: the work area is equipped with a manual gas tap and IP-44 electrical socket.
Code
|
Model
|
Useful dimensions mm
|
Overall dimensions mm
|
Power
|
Weight
|
|
|
W
|
H
|
D
|
W
|
H
|
D
|
Kw
|
Kg.
|
O74 500320
|
VS-4
|
1220
|
640
|
580
|
1312
|
1430
|
765
|
0.6
|
163
|
O74 500325
|
VS-5
|
1525
|
640
|
580
|
1617
|
1430
|
765
|
0.7
|
198
|
O74 500330
|
VS-6
|
1830
|
640
|
580
|
1922
|
1430
|
765
|
0.8
|
225
|
Working aperture mm
|
Exhaust duct Æ
|
Temperature rise
|
Volts
Hz
|
Noise level
dBA
|
Lighting
lux
|
Vibration
mm rms
|
170mm
|
105mm
|
<3° C
|
230/50
|
<59
|
>900
|
<0.006
|
ACCESSORIES
Code
|
Description
|
O74 704240
|
Epoxy powder painted modular stand for VS-4
|
O74 704260
|
Epoxy powder painted modular stand for VS-5
|
O74 704280
|
Epoxy powder painted modular stand for VS-6
|
O74 700500
|
UV Lamp for VS-4 on stainless steel front closure
|
O74 700510
|
UV Lamp for VS-5 on stainless steel front closure
|
O74 700520
|
UV Lamp for VS-6 on stainless steel front closure
|
O74 704360
|
Exhaust charcoal filter
|
O74 704340
|
Additional exhaust HEPA filter
|
O74 700780
|
Hour Counter
|
O74700740
|
Digital anemometer
|
O74 700750
|
Digital anemometer and automatic regulator
|
O74 709076
|
D.O.P. inlet
|
O74 700660
|
Set of 2 gas springs for frontal glass
|
O74 700770
|
Additional service connection for electrical power
|
O74 700760
|
Additional service connection for gas/vacuum (manual tap)
|